KeContact P20 

Charging station 

UDP Programmers Guide V 3.00 

 
 
 
 
 
 
 
 
 
 

Original manual 

 

Содержание KeContact P20

Страница 1: ...KeContact P20 Charging station UDP Programmers Guide V 3 00 Original manual...

Страница 2: ...meanings Notice Notes on use of equipment and useful practical tips are identified by Notice Notices do not con tain any information that draws attention to potentially dangerous or harmful functions...

Страница 3: ...ommands 5 2 1 General information 5 2 2 Supported UDP commands 5 2 3 UDP Broadcast Messages 6 2 4 UDP command i 7 2 5 UDP command failsafe 7 2 6 UDP command report 8 2 7 UDP command ena 10 2 8 UDP com...

Страница 4: ...realize e g a reduction of your energy con sumption in conjunction with a photovoltaic system and your charging station Schematic overview example 1 1 Requirements The following requirements have to...

Страница 5: ...nt to the charging station as simple text commands without end characters such as CR or LF The answers come as data packages with up to 512 bytes and are formatted in JSON standard each data line with...

Страница 6: ...RFID not enabled 2 ready for charging waiting for EV charging request S2 3 charging 4 error 5 authorization rejected Plug Current condition of the loading connection 0 unplugged 1 plugged on charging...

Страница 7: ...l the next startup of the device 1 Saves the settings into the EEPROM in order to activate the failsafe function automatically after restarting the device By default this feature is disabled and must...

Страница 8: ...put 0 Input 0 Serial 15017355 Sec 4294967296 Description ID ID of the retrieved report State Current state of the charging station 0 starting 1 not ready for charging e g unplugged X1 or ena not enabl...

Страница 9: ...energy limit Output State of the output X2 Input State of the potential free Enable input X1 When using the input please pay attention to the information in the installation manual Serial Serial numbe...

Страница 10: ...adcast message ATTENTION Some electric vehicles EVs do not yet meet the standard requirements and an ena 0 can lead to an error in the charging station 2 8 UDP command curr UDP command curr n Reply TC...

Страница 11: ...eiving of the command and not the cor rectness of the value Values between 2 and 9 are not answered reserved functions Invalid values e g letters are leading to a deactivation of the relay The correct...