US - 37
5.3
Parameter summary
The CP parameters are the parameter selections defined by KEB. You need an application
manual in order to get access to the entire parameter list.
Display
Parameter
Setting range
Resolution
Factory
setting
CP.0
Password input
0…9999
1
–
CP.1
Status display
–
–
Read Only
CP.2
Main Line Frequency
–
0.1 Hz
Read Only
CP.3
AC-Phase current L1
–
0.1 A
Read Only
CP.4
AC-Phase current L2
–
0.1 A
Read Only
CP.5
AC-Phase current L3
–
0.1 A
Read Only
CP.6
Actual Load
–
1 %
Read Only
CP.7
Actual Load / peak value
–
1 %
Read Only
CP.8
DC output current
–
0.1 A
Read Only
CP.9
Actual DC voltage
–
1 V
Read Only
CP.10
DC voltage / peak value
–
1 V
Read Only
CP.11
Heat sink temperature
–
1 °C
Read Only
CP.12
Over load counter
–
1 %
Read Only
CP.13
Active power
–
0.1 kW
Read Only
CP.14
Total regen kWhr counter
–
0.1 kWh
Read Only
CP.15
Total motor
kWhr counter
–
0.1 kWh
Read Only
CP.16
Total net
kWhr counter
–
0.1 kWh
Read Only
CP.17
Apparent power / Line input
–
0.1 kVA
Read Only
CP.18
Analog output 1 / amplification factor
-20.00…20.00
0.01
1.00
CP.19
DC bus switching level
+/-30000.00
0.01
550.00
CP.20
Auto error reset counter
0...10
1
3
CP.21
Last Error
-
-
Read Only
CP.22
Last Error 1
-
-
Read Only
CP.23
Last Error 2
-
-
Read Only
CP.24
Last Error 3
-
-
Read Only
CP.25
Last Error 4
-
-
Read Only
CP.26
Last Error 5
-
-
Read Only
CP.27
Last Error 6
-
-
Read Only
CP.28
Last Error 7
-
-
Read Only
CP.29
Software version
-
-
1.4
CP.30
Software date code
DDMM.Y
-
Read Only
CP.32
Pulse off level
-100kW...0.0kW
0.1kW
-0.8kW
CP.33
Operating mode
0...3
1
0
CP.34
Control angle
0.0...60.0
0.1
22.0
CP.35
Input Type
PNP or NPN
-
PNP
Содержание combivert R6-S