24
CP-Parameter for open-loop operation
Co-domain
Setting Description
-1
KEBdef/cust.par/sel.sets. Default values are copied in all parameters of
set 0 (exception: system and security parameters). If the target set is >
0 only programmable parameters are copied.
-2
KEBdef/cust.par/all sets. Default values are copied in all parameters of
all sets (exception: system and security parameters).
-3
KEBdef/cust+sys/sel.sets. Default values are copied in all parameters
of the target set (exception: security parameters). If the target set is > 0
only programmable parameters are copied.
-4
KEBdef/cust+sys/all sets. Default values are copied in all parameters of
all sets (exception: security parameters).
Attention
All definitions defined by the machine builder are reset by loading the
default values! This can include the terminal assignment, set changeo-
ver or operating conditions. Ensure before loading the default set that
there are no unwanted operating conditions.
CP48 Software version
see chapter 2.1