10
CP-Parameter for open-loop operation
CP00 Password input
see chapter 2.2
CP01 Actual value display
Co-domain
Description
0…±400 Hz
Display of the actual output frequency in Hz. The rotation of the inverter
is displayed by the sign.
Examples:
18.3
Output frequency 18,3 Hz, rotation forward
-18.3
Output frequency 18,3 Hz, rotation reverse
CP02 Set frequency display
Co-domain
Description
0…±400 Hz
Display of actually set value. For control reasons the set speed is dis-
played, even if the control release or direction of rotation is not switched.
If no direction of rotation is set, the set frequency for clockwise rotation
(forward) is displayed.
CP03 Inverter state
The actual operating condition of the inverter (e.g. forward constant run, standstill) is dis-
played in parameter „inverter state“. In the case of an error the current error message is dis-
played, even if the display has already been reset with ENTER (status LED is still blinking).
Display
State
no operation
modulation switched off; output voltage = 0 V; drive is not controlled.
no direction of rota-
tion preset
modulation switched off; output voltage = 0 V; drive is not controlled.
Acceleration
Forward
drive accelerates with direction of rotation forward.
Deceleration
Forward
drive decelerates with direction of rotation forward.
Acceleration
Reverse
drive accelerates with direction of rotation reverse.
Deceleration
Reverse
drive decelerates with direction of rotation reverse.
Speed dependent
Forward
Drive runs with constant speed and direction of rotation forward.
Speed dependent
Reverse
Drive runs with constant speed and direction of rotation reverse.
Other status messages are described at the parameters, on which they occur (see chapter
„Error Diagnosis“).
Содержание COMBIVERT G6