GB - 20
Parameter Description
3.
Parameter Description
On delivery the KEB COMBIVERT G6 is assigned with an user menu, the customer parame-
ters (CP-Parameters). These represent a selection of important parameters for the operation.
Up to a maximum of 48 customer parameters can be defined from over 500 parameters.
Only parameter CP00 password input is predefined and can not be modified or deleted.
Depending on the unit, there are three different customer parameter menus:
•
for open-loop operation
00G6N1B-C000
•
for ASCL operation
00G6N1B-H000
•
for SCL operation
00G6N1B-J000
The menu to be used can be determined from parameter CP48 (see below).
CP48
Software version
Co-domain
Setting Description
0.0.0.0 … F.F.F.F
–
Display of the software version
The first two digits display the major and minor version number (e. g.
1.2.x.x
→
V1.2)
The third digit displays the power unit software (open-loop, ASCL, SCL).
Depending therefrom there are different customer parameter menu im-
plemented. The corresponding instruction manuals are shown in the fol-
lowing table.
Power unit software
Instruction manual
Material Number
x.x.0.x Power unit open-loop 1st version
00G6N1B-C000
x.x.1.x
Power unit open-loop 2nd ver-
sion
00G6N1B-C000
x.x.2.x
Power unit ASCL
00G6N1B-H000
x.x.3.x
Power unit SCL
00G6N1B-J000
The fourth digit displays a serial number for the date code.
The instruction manuals are also available for download on our homepage.