GB - 17
Control circuit
Input
Factory setting of the digital inputs
Name
PIN
open-loop operation
closed-loop operation
RST
5
reset
ST
6
Control release
R
7
Direction of rotation reverse
F
8
Direction of rotation forward
I1
10
Fixed frequen-
cy 1
Fixed frequency
3
Fixed value 1
Fixed value 3
I2
9
Fixed frequen-
cy 2
Fixed value 2
I3
12
External error input (E.EF)
I4
11
Activates the DC braking
–
2.1.5.4 Connection of the digital outputs
Examples for the connection of the digital outputs
Connection appliance
Connection to an external control
15
13
14
15
13
14
COM
DI1
DI2
Example for the control of digital inputs and outputs
5 7
3
9 1113
6 8
4
101214
Output
Factory setting of the digital outputs
Name
PIN
O1
14
Switches at actual value=setpoint
O2
13
Ready signal