27
Operator parameters
Name:
1
st
receive PDO Mapping
Default value:
3
Note:
Value "0" deactivates the processing of this PDO. When activating the
PDO by writing a value unequal to zero the operator first checks the pro
-
cess data mapping for general validity. Then this mapping is converted
into the inverter process data assignment and written to the inverter
control. If everything could be done without error, the process data as-
signment is activated and stored non-volatile.
Subindex:
1-4: Nth mapped object
Meaning:
Indicates an object mapping.
Data length:
4 byte
Coding:
According to
[2]
as follows:
Byte7
Byte6
Byte5
Byte4
Index
Subindex *
Bitlength
HB
LB
* The coding of the subindex is not fixed =>
4.3.1.1
Please note that the sequence in the CAN telegram follows the Intel for-
mat. That means that the first byte (byte4) in the CAN telegram contains
the bit length of this mapping and the last byte (byte7) contains the high-
byte of the index.
Default value:
see above
Note:
Writing on the mapping automatically deactivates the PDO operation by
resetting the value of subindex „0“ to zero. Please note that not all pa-
rameters of the inverter control can be mapped to process data. Opera-
tor parameters can not be mapped to process data.
Содержание COMBIVERT F5
Страница 2: ...2...