7 Operator Parameters
The operator parameters set the configuration of the G6 VARAN control. Furthermore,
the software version as well as the current status can be read.
Id-Text
Name
Parameter index
os00
operator identifier
0x2080
Meaning
Displays the control card type, as well as the software version.
Type
Variable
Data length
32 bit
Access
read
Coding
e.g.: 150600
15xxxx: G6
xx06xx: VARAN
xxxx00: Version of the configuration parameters
Standard value: Device-dependent
Note
-
Id-Text
Name
Parameter index
os02
software date OS
0x2082
Meaning
Software date of the control card
Type
Variable
Data length
32 bit
Access
read
Coding
0.0000…9999, 3112:
The year is displayed before the comma, month and day are
after that. 2012,0813 means 13.08.2012.
Standard value: 0.0000
Note
-
Id-Text
Name
Parameter index
os03
software version
0x2083
Meaning
Software version of the control card
Type
Variable
Data length
32 bit
Access
read
Coding
0.0.0.0…255.255.255.255
e.g.: 1.3.0.1
Standard value: 0.0.0.0
Note
-
23
OPeRATOR PARAMeTeRS
Содержание COMBIVERT CONTROL G6 VARAN
Страница 2: ......
Страница 32: ...32 NOTES ...