17
bASIC SAfETY INSTrUCTIONS
Switching at the output
Switching between motor and drive converter is prohibited for single drives during op-
eration as this may trigger the protection gear of the device. Function speed search must
be activated if switching can not be avoided. Control release may only be triggered after
closing the motor contactor (e.g. by switching the control release).
Connecting and disconnecting is permissible with multiple motor drives if at least 1 mo-
tor is running during the switch-over process. The drive converter must be dimensioned
to the occurring starting currents.
The speed search function must be activated if the motor is still running during a restart
of the drive converter (mains on) (e.g. due to large rotating masses).
1.6 Maintenance
Die folgenden Wartungsarbeiten sind nach Bedarf, mindestens jedoch einmal pro Jahr,
durch autorisiertes und eingewiesenes Personal durchzuführen.
►
Check unit for loose screws and plugs and tighten if necessary.
► Clean motor from dirt and dust deposits. Pay attention especially to cooling fins and
protective grid of the fans.
►
Check the function of the fans of the drive converter. The fan must be replaced in
case of audible vibrations or squeak.
1.7 repair
In case of malfunction, unusual noises or smells inform a person in charge!
DANGEr
Unauthorized exchange, repair and modifications!
Unpredictable malfunctions!
► Modification or repair is permitted only by KEB Automation KG au
-
thorized personnel.
►
Only use original manufacturer parts.
►
Infringement will annul the liability for resulting consequences.
In case of failure, please contact the machine manufacturer. Only the manufactor can
provide an appropriate replacement or induce the maintenance.