KEB 00.F4.010-3009 Скачать руководство пользователя страница 8

GB 8

START

STOP

START

STOP

The mode FU_OP (Upload) can be locked, to make sure that the data
stored in the operator can not be overwritten.The status is displayed by
pressing the POWER-ON button and the „FUNC.-key“ simultaneously.

Lock Mode FU_OP:

Enable Mode FU_OP:

enable mode

FU_OP (Upload)

locked the
mode FU_OP

goes back into
normal operation

Locked mode

FU_OP (Upload)

goes back into
normal operation

release of
mode FU_OP

FUNC.

SPEED

FUNC.

SPEED

Press

Switch on

Inverter

Press

Switch on

Inverter

START

START

STOP

START

START

STOP

To adjust the baud rate of the operator to the baud rate at FU, the operator
can operate with 9600 baud or with 19200 baud. The actual adjusted
baud rate is displayed by pressing the POWER-ON button and the
„START-key“ simultaneously.

Increase Baud Rate:

Decrease Baud rate:

Press

Switch on

Inverter

9600 Baud

increase baud rate
to 19200 baud

goes back into
normal operation

Press

 Switch on

Inverter

19200 Baud

goes back into
normal operation

decrease baud ra-
te to 9600 baud

After changing of the baud rate the display of the operator goes into nor-
mal operation.

3.2 Changing of the

Baud Rate

3. Special functions

3.1 Lock Mode FU_OP

Содержание 00.F4.010-3009

Страница 1: ...7 2003 PM F4 01B K102 KEB Memory Operator Memory Operator BETRIEBSANLEITUNG INSTRUCTION MANUAL...

Страница 2: ...D 2...

Страница 3: ...eration as Memory Operator GB 6 2 2 1 Upload GB 7 2 2 2 Download GB 7 2 2 3 Abort and Fault Acknowledgement GB 7 3 Special Functions GB 8 3 1 Interlock of the Mode FU_OP GB 8 3 2 Changing of the Baud...

Страница 4: ...anufactures and distributes static frequency inverters worldwide in the industrial power range Within the scope of automization systems are needed which are more powerful and flexible With this in min...

Страница 5: ...the operation of the Memory Operator the Drive Mode in COMBIVERT F4 S4 may not be activated because the key assignment overlaps with the memory mode 2 1 Operation as Digital Operator wait until the d...

Страница 6: ...Mode FU_OP Upload can be locked to make sure that the data stored in the operator can not be overwritten see also section 3 1 Lock of the Mode FU_OP Frequency inverter or servo controller was not rec...

Страница 7: ...oad completed Confirms the Download Hold for approx 5 sec switches to normal operation 2 2 3 Abort and Fault knowledgement With the Stop key a read or write process can be interrupted The error messag...

Страница 8: ...h on Inverter START START STOP START START STOP To adjust the baud rate of the operator to the baud rate at FU the operator can operate with 9600 baud or with 19200 baud The actual adjusted baud rate...

Страница 9: ...ENTER F R FUNC SPEED press Inverter Servo is in the CP Mode Inverter Servo in Drive Mode Enter the Drive Mode password in CP 0 Drive Mode The Drive Mode can not be exited when inverter type 45 agree w...

Страница 10: ...e 45 and connected e g type 46 inverter do not correspond All type numbers can be displayed In mode OP_FU Clear message by pressing the ENTER key download is stopped Clear message by pressing the STAR...

Страница 11: ......

Страница 12: ...1 49620101 FAX 0033 1 45767495 E mail sfkeb 4 wanadoo fr KEB UK Ltd 6 Chieftain Buisiness Park Morris Close Park Farm Wellingborough GB Northants NN8 6 XF Tel 0044 1933 402220 FAX 0044 1933 400724 In...

Отзывы: