1-800-KEATING
|
MIRACLEAN®GAS GRIDDLE
5
GAS LEAK TESTING
Prior to lighting your griddle:
1. Make sure all thermostats are turned all the
way down (counterclockwise), and the switches
are in the “OFF” position.
2. Open gas supply to griddle.
3. Have your plumber or gas company check for
leaks with a soap and water solution or sniffer.
(NEVER check with a fl ame!)
NOTE:
It is estimated that half of all service calls
made on Keating MIRACLEAN® Gas griddles result
from an inadequate gas supply. During installation,
have a gas company representative make certain that
the griddle is receiving adequate gas pressure and
volume.
OPERATING
ORIFICE
1. Turn off main gas supply valve.
2. Remove pressure measuring stud screw located
at the “out-fl ow” (closest to gas burner) of the
gas valve and attach a manometer.
3. Remove cover screw from the gas valve
governor adjustment valve.
4. Open main gas supply valve and start griddle
according to supplied instructions.
5. Once griddle is in operation, adjust governor
to the orifi ce pressure for the specifi c gas.
6. Turn griddle off, close main gas supply valve,
remove manometer, replace cover screw
and tighten cover screw into pressure
measuring
stud.
SPECIAL NOTICES
The griddle should be operated only in an area that
has good air circulation.
The griddle must be installed under an electrically
powered ventilating hood.
The operator should be properly trained to the func-
tioning of the griddle.
This instructions manual should be supplied to the
operator.
Constructional changes to the area where the griddle
is installed shall not affect the air supply to the
griddle.
The installation, start-up and changes required when
changing from one gas type to another can be per-
formed only by a certifi ed professional.
These griddles are intended only for commercial use
and are to be operated only by professionals.
It is required that the griddle is regularly inspected for
proper functioning. The frequency of inspections are
dependent of the griddle usage, however it should be
performed at least once a year.
NOTE:
After conversions, readjustments or service
work the griddle has to be tested for proper function-
ing. Basically the following applies:
Test for gas leaks.
Testing for correct air supply.
Testing of proper combustion and gas supply.
Testing of correct gas supply controls.
Testing the vent system of the installation location.
LIGHTING
1. Open the manual gas valve.
2. Turn the Main Power On/Off switch to the “ON”
position to light all of the pilots.
3. Set each thermostat to desired temperature
for cooking. When the griddle plate reaches
each temperature setting, the burners will
shut off.
NOTE:
The pilot will automatically attempt to light
three times before shut down.
If any of the pilots fail to stay lit, wait fi ve minutes
before attempting to re-light to allow any accumu-
lated gas to escape.
CONDITIONING THE PLATE
The Miraclean® Griddle plate has been “seasoned” at
the factory. The chrome surface, when heated, creates
a thin layer of chrome oxide which acts as a releasing
agent for food products. If you feel you need to recon-
dition the surface, the following instructions should be
followed:
1. Follow cleaning instructions on page
7.
2. Heat MIRACLEAN® Griddle to 200°C for one hour.
3. Lower thermostat to 175°C, allowing the
MIRACLEAN® Griddle to cool to about 175°C, as is
evident when griddle cycles on or surface thermom-
eter indicates correct temperature.
Figure 2
Thermostat in
“OFF” position (fully
counter clockwise)
Содержание Miraclean 2000+ Series
Страница 21: ...keatingofchicago com 18 24 27 30 36 48 GAS GRIDDLE WITH TWO THERMOSTATS WIRING DIAGRAM PRIOR TO 2004...
Страница 22: ...1 800 KEATING MIRACLEAN GAS GRIDDLE 19 GAS GRIDDLES WITH THREE THERMOSTATS WIRING DIAGRAM...
Страница 23: ...keatingofchicago com 20 GAS GRIDDLES 2008 WITH THREE THERMOSTATS WIRING DIAGRAM...
Страница 25: ...keatingofchicago com 22 GAS GRIDDLES WITH FOUR THERMOSTATS WITH ELECTRONIC IGNITION WIRING DIAGRAM...