background image

1-800-KEATING

 

|

   

MIRACLEAN®GAS GRIDDLE

5

GAS LEAK TESTING

Prior to lighting your griddle:

1.  Make sure all thermostats are turned all the 
       way down (counterclockwise), and the switches 
       are in the “OFF” position.

2.  Open gas supply to griddle.

3.  Have your plumber or gas company check for 
 

leaks with a soap and water solution or sniffer.  

 

(NEVER check with a fl ame!)

NOTE: 

It is estimated that half of all service calls 

made on Keating MIRACLEAN® Gas griddles result 
from an inadequate gas supply. During installation, 
have a gas company representative make certain that 
the griddle is receiving adequate gas pressure and 
volume.

OPERATING

ORIFICE

1.  Turn off main gas supply valve.

2.  Remove pressure measuring stud screw located 
 

at the “out-fl ow” (closest to gas burner) of the 

 

gas valve and attach a manometer.

3.  Remove cover screw from the gas valve 
 

governor adjustment valve.

4.  Open main gas supply valve and start griddle 

 

according to supplied instructions.

5.  Once griddle is in operation, adjust governor 
 

to the orifi ce pressure for the specifi c gas.

6.  Turn griddle off, close main gas supply valve, 
 

remove manometer, replace cover screw 

 

and tighten cover screw into pressure 

 measuring 

stud.

SPECIAL NOTICES

The griddle should be operated only in an area that 
has good air circulation.

The griddle must be installed under an electrically 
powered ventilating hood.

The operator should be properly trained to the func-
tioning of the griddle.

This instructions manual should be supplied to the 
operator.

Constructional changes to the area where the griddle 
is installed shall not affect the air supply to the 
griddle.

The installation, start-up and changes required when 
changing from one gas type to another can be per-
formed only by a certifi ed professional.

These griddles are intended only for commercial use 
and are to be operated only by professionals.

It is required that the griddle is regularly inspected for 
proper functioning. The frequency of inspections are 
dependent of the griddle usage, however it should be 
performed at least once a year.

NOTE:

 After conversions, readjustments or service 

work the griddle has to be tested for proper function-
ing. Basically the following applies:

Test for gas leaks.

Testing for correct air supply.

Testing of proper combustion and gas supply.

Testing of correct gas supply controls.

Testing the vent system of the installation location.

LIGHTING

1.  Open the manual gas valve.

2.  Turn the Main Power On/Off switch to the “ON” 
 

position to light all of the pilots.

3.  Set each thermostat to desired temperature 
 

for cooking. When the griddle plate reaches 

 

each temperature setting, the burners will 

 

shut off.  

NOTE: 

The pilot will automatically attempt to light 

three times before shut down.

If any of the pilots fail to stay lit, wait fi ve minutes 
before attempting to re-light to allow any accumu-
lated gas to escape.

CONDITIONING THE PLATE

The Miraclean® Griddle plate has been “seasoned” at 
the factory. The chrome surface, when heated, creates 
a thin layer of chrome oxide which acts as a releasing 
agent for food products. If you feel you need to recon-
dition the surface, the following instructions should be 
followed:

1. Follow cleaning instructions on page

 

7.

2. Heat MIRACLEAN® Griddle to 200°C for one hour.

3. Lower thermostat to 175°C, allowing the 
MIRACLEAN® Griddle to cool to about 175°C, as is 
evident when griddle cycles on or surface thermom-
eter indicates correct temperature.

Figure 2

Thermostat in
 “OFF” position (fully
counter clockwise)

Содержание Miraclean 2000+ Series

Страница 1: ...iddle from Malibu You are now enjoying the significant benefits a Keating chrome griddle provides over a standard griddle including 32 saving in energy consumption saving you money and reducing your c...

Страница 2: ...curs specifications may be changed without notice KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL IMPORTANT THIS MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR MODEL USE THE MIRACLEAN GAS GRIDDL...

Страница 3: ...proper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or...

Страница 4: ...serviced by qualified and or certified and or licensed service personnel Contact your distributor for assistance IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage...

Страница 5: ...ACLEAN surface takes just three easy steps scraping with the Keating Scraper washing with the Palmetto brush and water and using Keating Klenzer and a damp cloth to polish No more griddle bricks grill...

Страница 6: ...ly designed operating exhaust hood Connected to the type of gas for which the griddle is manufactured Governor is installed in the appliance and adjusted for the manifold pressure marked on the serial...

Страница 7: ...ppliances Quick disconnect devices must comply with the current European standard for quick disconnect devices for use with gas fuel as applicable IF DISCONNECTION OF THE RESTRAINT IS NEC ESSARY IT MU...

Страница 8: ...hanges required when changing from one gas type to another can be per formed only by a certified professional These griddles are intended only for commercial use and are to be operated only by profess...

Страница 9: ...ristics and heat retention properties found in the MIRACLEAN Griddle operating temperatures should be set 6 C to 14 C below conventional griddles 2 Locate the inverted V s on the front of the griddle...

Страница 10: ...g Klenzer BECAUSE OF THE SUPERIOR MIRACLEAN SURFACE THE ONLY TOOLS YOU WILL EVER NEED TO CLEAN THE GRIDDLE ARE A NATURAL BRISTLE BRUSH AND A KEATING SCRAPER NEVER USE A GRIDDLE STONE BRICK OR SCREEN T...

Страница 11: ...mometer 1 Set thermostat to desired temperature 150 C recommended 2 Allow thermostat to cycle three times 3 Locate V on front of griddle plate See Figure 3 above thermostat to be calibrated to locate...

Страница 12: ...e burners to burn properly Any objects placed in the flue such as steak weights egg covers pans rags and utensils will not allow the burners to burn properly causing poor griddle performance and healt...

Страница 13: ...t b Replace main Power On Off switch Pilot won t light Burners won t light a Gas isn t turned on or air is in gas line b Thermostat isn t on c Thermostat is out of calibration or is faulty d Main Powe...

Страница 14: ...ng four screws and support the panel to prevent damage to wiring or other components 6 Remove two screws which hold thermostat body to control panel 7 Detach wires from thermostat body carefully not i...

Страница 15: ...n off gas 3 Remove control panel by removing four screws and support it to prevent damage to wiring or other components 4 Disconnect wires from gas valve carefully noting connections 5 Remove burner t...

Страница 16: ...ver clockwise to increase and counterclock wise to decrease to adjust flames for all burners fed by each valve 2 Air adjustment loosen screw for air shutter locat ed on front of burner and rotate air...

Страница 17: ...ox rear mount 022448 module box bottom mount 022448 module mounted in 059819 module box 022448 module inside griddle 059819 module Kit or Part to order Kit 060025 Kit 060026 Kit 060068 Part 022448 Par...

Страница 18: ...D MAIN POWER ON OFF 011539 2 CONTROL PANEL REFERENCE ONLY 3 THERMOSTAT 175 550 F w shield 029519 4 THERMOSTAT DIAL PLATE FOR 100 280 C THERMOSTAT 034972 5 THERMOSTAT KNOB FOR 100 280 C THERMOSTAT 0099...

Страница 19: ...13P CZECH REPUBLIC CZ 12H 13P GERMANY DE 12E 13P FRANCE FR 12ER 12ER 13P GREECE GR 12H 13P IRELAND IE 12H 13P ITALY IT 12H 13P NETHERLANDS NL 12L 13P PORTUGAL PT 12H 13P SPAIN ES 12H 13P SWEDEN SE 12H...

Страница 20: ...hooting and maintenance The wiring diagrams in this section cover standard griddles which may or may not match the diagram attached to the griddle Non standard griddles with additional thermostats do...

Страница 21: ...keatingofchicago com 18 24 27 30 36 48 GAS GRIDDLE WITH TWO THERMOSTATS WIRING DIAGRAM PRIOR TO 2004...

Страница 22: ...1 800 KEATING MIRACLEAN GAS GRIDDLE 19 GAS GRIDDLES WITH THREE THERMOSTATS WIRING DIAGRAM...

Страница 23: ...keatingofchicago com 20 GAS GRIDDLES 2008 WITH THREE THERMOSTATS WIRING DIAGRAM...

Страница 24: ...1 800 KEATING MIRACLEAN GAS GRIDDLE 21 60 72 GAS GRIDDLES WITH THREE THERMOSTATS WITH ELECTRONIC IGNITION WIRING DIAGRAM PRIOR TO 2008...

Страница 25: ...keatingofchicago com 22 GAS GRIDDLES WITH FOUR THERMOSTATS WITH ELECTRONIC IGNITION WIRING DIAGRAM...