keatingofchicago.com
10
SERVICE DIAGNOSIS
A properly adjusted Keating MIRACLEAN® Gas Griddle, with no load, will cycle “on” approximately every 2-1/2
to 3 minutes. Each cycle will last approximately three minutes, ensuring that the temperature setting is held
within a narrow band.
The burners, when on, will produce fl ames directed at the bottom of the griddle plate. The fl ames should be
about 25mm to 38mm below the bottom of the plate.
CAUTION - To avoid injury or equipment damage:
· When servicing equipment, use proper tools and supplies.
· Refer to Service Manual for instructions.
Every Keating MIRACLEAN® Gas Griddle has safety controls to ensure safe operation and guard against compo-
nent failure. Operation, removal and replacement of each control is explained in the SERVICE section, page 11.
The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that
you use a qualifi ed & licensed service company.
NOTE:
To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
TROUBLE SHOOTING CHART
PROBLEM
PROBABLE CAUSE
SOLUTION
Main Power On Light doesn't come on
a. No electricity to griddle.
b. Main Power On/Off switch light is
faulty.
a. Plug griddle into approved working
outlet.
b. Replace main Power On/Off switch.
Pilot won't light
Burners won't light
a. Gas isn’t turned on or air is in gas line.
b. Thermostat isn't on.
c. Thermostat is out of calibration or is
faulty.
d. Main Power On/Off switch is faulty.
e. Thermostat I/O switch is faulty.
f. Gas pressure too low.
g. Spark electrode(s) is faulty or
connections are loose.
h. Clogged pilot orifi ce.
i. Spark module(s) is faulty.
j. Gas valve is faulty.
k. Transformer is defective.
a. Turn manual gas valve on. If using
fl exible connector with quick
disconnect, make sure quick
disconnect is completely engaged.
b. Turn thermostat to desired
temperature.
c. Check calibration of thermostat (see
page 8) and replace if necessary (see
pages 10, 11)
d. Replace Main Power On/Off switch.
e. Replace I/O switch.
f. Adjust gas pressure.
g. Tighten connections. Replace
electrode(s) if faulty.
h. Turn griddle and manual gas valve off.
Clean orifi ce.
i. Replace spark module(s).
j. Replace gas valve.
k. Replace transformer.
Temperature of griddle is erratic
a. Thermostat out of calibration or faulty.
b. Thermostat bulb is improperly placed.
c. Exhaust problems or drafts in kitchen.
a. Check calibration of thermostat (see
page 8) and replace if necessary (see
pages 11, 12).
b. Adjust bulb position (see page 11,
THERMOSTAT BULB POSITIONING.)
c. Contact your HVAC representative.
Electrode continues to spark
a. Low pilot fl ame height.
b. Spark module(s) is faulty.
a. Adjust pilot fl ame height (see
page 13)
FLAME ADJUSTMENT.
b. Replace spark module(s).
Содержание Miraclean 2000+ Series
Страница 21: ...keatingofchicago com 18 24 27 30 36 48 GAS GRIDDLE WITH TWO THERMOSTATS WIRING DIAGRAM PRIOR TO 2004...
Страница 22: ...1 800 KEATING MIRACLEAN GAS GRIDDLE 19 GAS GRIDDLES WITH THREE THERMOSTATS WIRING DIAGRAM...
Страница 23: ...keatingofchicago com 20 GAS GRIDDLES 2008 WITH THREE THERMOSTATS WIRING DIAGRAM...
Страница 25: ...keatingofchicago com 22 GAS GRIDDLES WITH FOUR THERMOSTATS WITH ELECTRONIC IGNITION WIRING DIAGRAM...