Your ventilation hood, when installed, must conform

to the current ANSI/NFPA 96 standard (latest

edition).

l

No frame or restriction shall be constructed around

the fryer that will restrict air movement into the

fryer’s combustion area (through the grease filter

underneath the fryer) or prevent proper ventilation.

l

Keating fryers are designed to operate on the gas

fuel specified on the serial plate and must not be

operated with another gas fuel. They cannot be

converted to another gas fuel by turning or engaging

a switch.

FOR YOUR SAFETY: Do not store or use gasoline

or other flammable vapors and liquids in the

vicinity of this or any appliance.

You will post, in a prominent location, instructions to be

followed in the event the user smells gas. This

information shall be obtained from your local gas

supplier. You may use the yellow stick-on label

temporarily until you receive the data from your local gas

supplier.

IMPORTANT: In the event a gas odor is detected,

shut down unit at main shut-off valve and contact

the local gas company or gas supplier for

emergency service.

l

Suitable for installation on combustible floors.

l

You must maintain this appliance free and clear from

combustibles.

l

You must maintain the following minimum

clearances from combustible and noncombustible

construction:

l

You must install this appliance at least 16 inches

away from any open flame.

l

Adequate clearance for servicing and proper

operation must be maintained. Your fryer is designed

to be serviced from the front.

l

Keating commercial fryers are intended for other

than household use.

l

ALWAYS instruct new employees on proper fryer

operation.

l

A fryer should be operated ONLY by properly trained

personnel.

l

ALWAYS turn fryer off each night.

l

ALWAYS disconnect fuel source before servicing.

l

NEVER leave a fryer unattended during operation.

l

NEVER move a fryer when full of hot oil.

l

NEVER introduce objects or liquids into fryer, while

operational, which are not designed or made for

cooking.

l

THIS FRYER MAY NOT BE ALTERED, MODIFIED

OR CHANGED IN ANY WAY. 

The State of California enacted the California Safe

drinking water and Toxic Enforcement Act of 1986,

(Prop. 65), which “prohibits any person in the course of

doing business from knowingly and intentionally

exposing any individual to a chemical known to the

State of California to cause cancer or reproductive

toxicity without first giving clear and reasonable

warning to such individuals.” The Governor’s Scientific

Advisory Panel added carbon monoxide to the list of

hazardous chemicals known to cause reproductive

harm.
In order to establish full compliance with Proposition

65, we attached a yellow warning label to each gas

fired appliance manufactured by Keating of Chicago,

Inc.
Carbon monoxide would not be present in

concentrations that would pose a “significant risk” to

the consumer when the equipment is installed,

operated and maintained as follows:

l

Installed in accordance with all local codes, or in the

absence of local codes, with the current National

Fuel Gas Code ANSI Z223.1/NFPA 54 (latest

edition).

l

Installed under a properly designed operating

exhaust hood.

l

Connected to the type of gas for which the appliance

is manufactured.

l

In-line pressure regulator, not supplied by Keating,

must be installed outside the appliance.

l

The appliance is adjusted for the manifold pressure

marked on the serial plate.

l

Adequate air supply to the appliance.

l

The equipment is operated in the manner intended

using the proper utensils.

l

Keep the equipment clean and have it checked

periodically.

l

Burner air adjustments, mechanical maintenance

and repairs must be performed by qualified service

personnel.

If the equipment is not installed, operated and

maintained in accordance with the above,

concentrations of carbon monoxide in excess of the

established limits could be present in the kitchen

environment.

Clearances

Combustible 

Noncombustible

Construction

 Construction

Back

6" 0"

Right Side

6"

0"

Left Side

6"

0"

Содержание INCREDIBLE FRYING MACHINE

Страница 1: ...o os se e W Wh ho o S Se er rv ve e T Th he e V Ve er ry y B Be es st t INCREDIBLE FRYING MACHINE GAS FRYER Service Manual KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicag...

Страница 2: ...Timers 7 8 SECTION IV MAINTENANCE Warranty Repairs 8 Preventive Maintenance 8 Oil Breakdown 8 Thermostat Calibration 9 Thermostat Bulb Positioning 9 10 SECTION V SERVICE DIAGNOSIS Removal Replacement...

Страница 3: ...ATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS...

Страница 4: ...ignition system 120 VAC 9 neoprene cord with 3 pronged grounded plug Instant recovery to cooking temperature High temperature stainless steel flue lining 100 factory testing STANDARD ACCESSORIES Keati...

Страница 5: ...NEVER introduce objects or liquids into fryer while operational which are not designed or made for cooking l THIS FRYER MAY NOT BE ALTERED MODIFIED OR CHANGED IN ANY WAY The State of California enact...

Страница 6: ...g at test pressures above 1 2 psig 3 45 KPA fryer must be disconnected from gas supply piping system Counter model and flood model fryers must be restrained to prevent tipping when installed in order...

Страница 7: ...propriate battery piping size ELECTRICAL CONNECTION The Keating Incredible Frying Machine IFM is equipped with a 9 neoprene covered 3 wire electrical cord with a three pronged grounded plug for protec...

Страница 8: ...e has been provided to ensure optimum cooking while ensuring the safety of the operator Do not overfill the fryer vessel Figure 3 1 Fill Level Line Fill the fryer vessel with oil or MELTED solid short...

Страница 9: ...or fryers with automatic basket lift a buzzer will sound and the basket s will rise automatically Allow oil to drain before removing 7 Place basket s on basket hanger rods on splashback of fryer and a...

Страница 10: ...into a dry suitable receptacle and remove from cooking area 11 Spread Keating Klenzer liberally on tubes and sides of fryer vessel 12 A non abrasive scouring pad may be used to remove the now softene...

Страница 11: ...output contacts will close CANCELING A CYCLE To cancel a cycle in progress press and hold any button for approximately two seconds The relay output contacts will open and the display will show the ti...

Страница 12: ...s too loose will overshoot Overshoot The thermostat takes a long time to cycle and then misses its preset temperature by 20 F 40 F yielding a poor quality product n If the bulb is too tight the paper...

Страница 13: ...e air shutter is located in the front of the blower cabinet where the two air hoses enter the cabinet It consists of two plates each located directly above an air hose and held in place by a hex head...

Страница 14: ...ht light is faulty c If Over Maximum Temperature c Reset Hi Limit after oil has cooled light is on Hi Limit has down below 425 F Correct problem been activated which caused Hi Limit to activate See pa...

Страница 15: ...ation b Calibrate thermostat See page 9 Calibration Oil in fryer vessel smokes a Oil has begun to breakdown a Replace oil b High carbon content in oil b Filter oil completely replace if necessary c Di...

Страница 16: ...BURNER ASSEMBLY SEE PAGE 17 2 17 BURNER ORIFICE NATURAL GAS 14 IFM 016502 2 18 IFM 021869 2 20 IFM 021869 2 18 FRYER VESSEL INSULATED CALL 1 800 KEATING 1 19 DRAIN VALVE FRONT 1 14 IFM 016884 1 DRAIN...

Страница 17: ...14 NOTE Part numbers correspond with the Incredible Frying Machine IFM Gas Fryer Parts List on Page 13 INCREDIBLE FRYING MACHINE IFM GAS FRYER ASSEMBLY I...

Страница 18: ...15 NOTE Part numbers correspond with the Incredible Frying Machine IFM Gas Fryer Parts List on page 13 INCREDIBLE FRYING MACHINE IFM GAS FRYER ASSEMBLY II...

Страница 19: ...R SWITCH LIGHTED MAIN ON OFF 1 015119 9 ROCKER SWITCH HI LIMIT TEST 1 015384 10 KEATING TIMER 2 023709 11 TIMING RELAY INSTANT ON 2 016189 12 RELAY BASKET LIFT AND INSTANT ON 2 008088 13 CONTROL PANEL...

Страница 20: ...PLACEMENT KIT 1 NATURAL GAS 052562 LP GAS 052908 3 OBSERVATION WINDOW ASSEMBLY LENS 016101 COVER 1 015905 4 BURNER OUTER PLATE ELBOW ASSEMBLY LEFT OR RIGHT SIDE 1 022158 5 BURNER TO PLATE SEALING GASK...

Страница 21: ...IN RELIEF PLASTIC 1 000470 000470 7 WIRING HARNESS NOT SHOWN 1 N A N A 8 AIR PLENUM 1 020816 025960 9 AIR SHUTTER LEFT 1 020273 025662 RIGHT 1 020607 025663 10 BLOWER BOX REAR COVER 1 1 800 KEATING 1...

Страница 22: ...19 VIII WIRING DIAGRAMS 14 IFM WOSA 120V CONNECTION DIAGRAM KEATING ELECTRONIC TIMERS...

Страница 23: ...20 18 20 IFM 120V CONNECTION DIAGRAM KEATING ELECTRONIC TIMERS...

Страница 24: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Страница 25: ..._________________ ADDRESS ______________________________________________________________________________________________________ CITY __________________________________________________________________...

Отзывы: