Keating Of Chicago INCREDIBLE FRYING MACHINE Скачать руководство пользователя страница 14

11

VI SERVICE DIAGNOSIS

A properly adjusted Keating Incredible Frying Machine Gas Fryer (IFM), with no load, will cycle “On” approximately

every 2-1/2 to 3 minutes. Each cycle will last 15 to 25 seconds, ensuring that the temperature setting is held within

a narrow band.

l

Every Keating Incredible Frying Machine Gas Fryer (IFM) has a number of safety controls to ensure safe

operation and guard against component failure. 

A. Trouble shooting chart

The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you

use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service

company.

NOTE: 

To correctly and quickly diagnose the system, the chart below must be followed in sequential order.

PROBLEM

PROBABLE CAUSE

SOLUTION

Main power light does not a. Fryer not plugged in.

a. Plug fryer into approved outlet.

come on.

Must be properly grounded.

b. Main power switch is faulty.

b. Replace the main power switch.

Blower light does not 

a. Thermostat not turned on.

a. Set thermostat to desired temperature.

come on.

b. If blower comes on, blower 

b. Replace blower light.

light is faulty.

c. If Over Maximum Temperature

c. Reset Hi-Limit after oil has cooled

light is on, Hi-Limit has

down below 425°F. Correct problem 

been activated.

which caused Hi-Limit to activate. (See

page 9)

d. If blower does not come on, 

d. Verify power to blower. Replace blower. 

blower is faulty.

Burner light does not 

l

Check for spark at each burner.

come on.

If no spark at either burner:

a. Purge time delay relay is faulty

a. Replace purge time delay relay.

(if it has no output voltage.)

b. Spark module is faulty.

b. Replace spark module.

l

Check for spark at each burner.

If spark occurs at both burners:

c. Burner light is faulty.

c. Replace burner light.

Burner light comes on,

l

Check for spark at each burner.

then goes out (after 2-1/2

If no spark at either burner:

seconds.)

a. Spark electrode wires are faulty.

a. Replace spark electrode wires.

b. Spark electrode is faulty or is

b. Align spark electrode. Replace

out of alignment.

spark electrode if faulty. Gap must be

l

Check for spark at each burner.

1/8" between electrode and pilot tube

If spark occurs at both burners:

and between pilot tube & burner.

c. Gas is not turned on.

c. Turn manual gas valve on. If using 

flexible connector with quick 

disconnect, make sure that the quick 

disconnect is completely engaged.

d. Combination gas valve is faulty.

d. Replace gas valve (verify voltage to 

the valve first).

Содержание INCREDIBLE FRYING MACHINE

Страница 1: ...o os se e W Wh ho o S Se er rv ve e T Th he e V Ve er ry y B Be es st t INCREDIBLE FRYING MACHINE GAS FRYER Service Manual KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicag...

Страница 2: ...Timers 7 8 SECTION IV MAINTENANCE Warranty Repairs 8 Preventive Maintenance 8 Oil Breakdown 8 Thermostat Calibration 9 Thermostat Bulb Positioning 9 10 SECTION V SERVICE DIAGNOSIS Removal Replacement...

Страница 3: ...ATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS...

Страница 4: ...ignition system 120 VAC 9 neoprene cord with 3 pronged grounded plug Instant recovery to cooking temperature High temperature stainless steel flue lining 100 factory testing STANDARD ACCESSORIES Keati...

Страница 5: ...NEVER introduce objects or liquids into fryer while operational which are not designed or made for cooking l THIS FRYER MAY NOT BE ALTERED MODIFIED OR CHANGED IN ANY WAY The State of California enact...

Страница 6: ...g at test pressures above 1 2 psig 3 45 KPA fryer must be disconnected from gas supply piping system Counter model and flood model fryers must be restrained to prevent tipping when installed in order...

Страница 7: ...propriate battery piping size ELECTRICAL CONNECTION The Keating Incredible Frying Machine IFM is equipped with a 9 neoprene covered 3 wire electrical cord with a three pronged grounded plug for protec...

Страница 8: ...e has been provided to ensure optimum cooking while ensuring the safety of the operator Do not overfill the fryer vessel Figure 3 1 Fill Level Line Fill the fryer vessel with oil or MELTED solid short...

Страница 9: ...or fryers with automatic basket lift a buzzer will sound and the basket s will rise automatically Allow oil to drain before removing 7 Place basket s on basket hanger rods on splashback of fryer and a...

Страница 10: ...into a dry suitable receptacle and remove from cooking area 11 Spread Keating Klenzer liberally on tubes and sides of fryer vessel 12 A non abrasive scouring pad may be used to remove the now softene...

Страница 11: ...output contacts will close CANCELING A CYCLE To cancel a cycle in progress press and hold any button for approximately two seconds The relay output contacts will open and the display will show the ti...

Страница 12: ...s too loose will overshoot Overshoot The thermostat takes a long time to cycle and then misses its preset temperature by 20 F 40 F yielding a poor quality product n If the bulb is too tight the paper...

Страница 13: ...e air shutter is located in the front of the blower cabinet where the two air hoses enter the cabinet It consists of two plates each located directly above an air hose and held in place by a hex head...

Страница 14: ...ht light is faulty c If Over Maximum Temperature c Reset Hi Limit after oil has cooled light is on Hi Limit has down below 425 F Correct problem been activated which caused Hi Limit to activate See pa...

Страница 15: ...ation b Calibrate thermostat See page 9 Calibration Oil in fryer vessel smokes a Oil has begun to breakdown a Replace oil b High carbon content in oil b Filter oil completely replace if necessary c Di...

Страница 16: ...BURNER ASSEMBLY SEE PAGE 17 2 17 BURNER ORIFICE NATURAL GAS 14 IFM 016502 2 18 IFM 021869 2 20 IFM 021869 2 18 FRYER VESSEL INSULATED CALL 1 800 KEATING 1 19 DRAIN VALVE FRONT 1 14 IFM 016884 1 DRAIN...

Страница 17: ...14 NOTE Part numbers correspond with the Incredible Frying Machine IFM Gas Fryer Parts List on Page 13 INCREDIBLE FRYING MACHINE IFM GAS FRYER ASSEMBLY I...

Страница 18: ...15 NOTE Part numbers correspond with the Incredible Frying Machine IFM Gas Fryer Parts List on page 13 INCREDIBLE FRYING MACHINE IFM GAS FRYER ASSEMBLY II...

Страница 19: ...R SWITCH LIGHTED MAIN ON OFF 1 015119 9 ROCKER SWITCH HI LIMIT TEST 1 015384 10 KEATING TIMER 2 023709 11 TIMING RELAY INSTANT ON 2 016189 12 RELAY BASKET LIFT AND INSTANT ON 2 008088 13 CONTROL PANEL...

Страница 20: ...PLACEMENT KIT 1 NATURAL GAS 052562 LP GAS 052908 3 OBSERVATION WINDOW ASSEMBLY LENS 016101 COVER 1 015905 4 BURNER OUTER PLATE ELBOW ASSEMBLY LEFT OR RIGHT SIDE 1 022158 5 BURNER TO PLATE SEALING GASK...

Страница 21: ...IN RELIEF PLASTIC 1 000470 000470 7 WIRING HARNESS NOT SHOWN 1 N A N A 8 AIR PLENUM 1 020816 025960 9 AIR SHUTTER LEFT 1 020273 025662 RIGHT 1 020607 025663 10 BLOWER BOX REAR COVER 1 1 800 KEATING 1...

Страница 22: ...19 VIII WIRING DIAGRAMS 14 IFM WOSA 120V CONNECTION DIAGRAM KEATING ELECTRONIC TIMERS...

Страница 23: ...20 18 20 IFM 120V CONNECTION DIAGRAM KEATING ELECTRONIC TIMERS...

Страница 24: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Страница 25: ..._________________ ADDRESS ______________________________________________________________________________________________________ CITY __________________________________________________________________...

Отзывы: