Controller Navigation - Menu Structure

Access Setpoint mode by pressing and holding the             button until 

tS (temperature setpoint) displays on the screen   

ENTER

Use the        up and      down arrows to scroll through the available setpoints.   

ENTER

Press              to view the current setting.

Indicator lights

Red  light - Basic Menu - not used
Yellow light - non-critical alarm (system running)
Green light - compressor on
Green flashing - compressor waiting on timer to start/stop

Use the        up and      to change the setpoint

ENTER

Press              to move between the digits to accelerate the changes.

ENTER

Press              and hold to confirm each setpoint change

BACK

Press              to escape.

therm

solutions

Energy Saving Refrigeration Controller

A

daptive

Control

.

Accessing the Menus

Press and hold 

for 3 seconds

BASIC MENUS

ADVANCED MENUS

Press and hold 

for 3 seconds

rtP

Clt

SySt

CPrl

dFrl

Fnrl

ALSt

Default menu - 

Non Adustable (view only)

VARIABLES MENU

tS

dtyP 

dFit

dPd

dFt

diF

OFFt

Runt

FrEF

AU1

StA1

AU2

StA2

tS2

tOd

d1

d2

d3

d4

d5

d6

d7

d8

d9

d10

d11

d12

dtSP

drnt

fdSP

Fndt

FndF

Pdt

HAO

LAO

tAd

Adr

Unt

CLAL

Schedule Defrost w. 

Custom Defrost Per Day

tS

dtyP 

dFit

dPd

dFt

diF

OFFt

Runt

FrEF

AU1

StA1

AU2

StA2

tS2

dtSP

drnt

fdSP

Fndt

FndF

Pdt

HAO

LAO

tAd

Adr

Unt

CLAL

Schedule 

Defrost

tS

dtyP 

dFit

dPd

dFt

diF

OFFt

Runt

FrEF

AU1

StA1

AU2

StA2

tS2

dPtr

HEtr

EdiF

dtSP

drnt

fdSP

Fndt

FndF

Pdt

HAO

LAO

tAd

Adr

Unt

CLAL

Demand 

Defrost

tS

dtyP 

dFit

HAO

LAO

tAd

Demand 

Defrost

tS

dtyP 

dFit

dPd

dFt

HAO

LAO

tAd

Schedule 

Defrost

tS

dtyP 

dFit

dPd

dFt

tOd

d1

d2

d3

d4

d5

d6

d7

d8

d9

d10

d11

d12

HAO

LAO

tAd

Schedule Defrost w. 

Custom Defrost Per Day

dPd  & dFt only 

visible if ScHd 

(schedule) is selected 

for DFit (defrost 

initiation mode) 

dPd & dFt only 

visible if ScHd 

(schedule) is 

selected for DFit 

(defrost initiation 

mode) 

tOd only visible if 

CUS (custom) is 

selected for dPd 

(defrosts per day) 

rtP

Clt

rt1 

or 

Ct1 

or

 tp1 

or

 din1

SyOn 

SyOF 

drOn 

drCL   

diOn 

diOF 

dLOC   

dAUt  

inid

tErd

T2OF

t2On

SySt

CPrl

dFrl

Fnrl

ALSt

depending on the 

use of the digital 

input (din1), 

controller will 

display one of these:

Basic Menu

If Auxiliary 

Input(s) Used

KE2 Adaptive

Control

Quick Start Guide

Содержание AdaptiveControl

Страница 1: ...rovided Conduit to go between the controller and the evaporator 2 Conduit connectors straight or elbow as required 8 High voltage wires matched to the load of the heaters fans liquid line solenoid and...

Страница 2: ...Vapor Mix Restrictor TEV or EEV Warm Liquid ColdVapor HotVapor Warm Air Cold Air Evaporator Compressor Condenser SaturationTemp F from receiver pressure LiquidTemp atValve F Subcooling Suction Pressu...

Страница 3: ...lect two places that are the last to defrost preferably at each end of the evaporator More often than not on coils the location of the sensor is a short distance from the end approximately 1 to 1 1 2...

Страница 4: ...e Control Cutalengthofconduittogofromthecontrollertotheevaporator Measure the distance between the controller and evaporator to account for the extra length necessary to properly route conduit Determi...

Страница 5: ...end of the conduit to the controller 5 5 115V 208 240V Wiring the controller Locate the Voltage Selector Switch It is a 2 position switch with red indicator The selected voltage will be displayed on...

Страница 6: ...lug the connectors to the COM and NO positions of the Liquid Line Solenoid Compressor Relay Liquid Line Solenoid LLS Comp Relay Using KE2 Wire Harness The yellow wires are used for Liquid Line Solenoi...

Страница 7: ...he controller to the plastic posts Connecting sensor wires to controller The temperature sensors are designed to be attached to the con troller using 2 position screw terminals The terminals are locat...

Страница 8: ...controller 15 Evaporator wiring Fans Strip the ends of the wires con nected to the KE2 Adaptive Control used to control the evapo rator fans The fan wires from the controller can be attached to the te...

Страница 9: ...ect L2 Neutral to the remain ing defrost leads The defrost safety should not be re moved from the circuit Its purpose is to prevent the heaters from over heating and causing damage 18 Copyright 2016 K...

Страница 10: ...ary 2016 Page 10 Copyright 2016 KE2 Therm Solutions Inc Washington Missouri 63090 Figure 8 Wiring Schematic Ladder Diagram Figure 8 Wiring Schematic Using KE2Terminal Board KE2 AdaptiveControl Quick S...

Страница 11: ...ew included The end with multiple loops is designed to hold the sensor Locate the best place to install the sensor The sensor should be located between 6 and 12 inches away from the face of the evapor...

Страница 12: ...erference being introduced into the sensor wires Interference can be introduced when sensor wires are located near high voltage lines High voltage is defined by Underwriter s Laboratories as above 30V...

Страница 13: ...venient loca tion where it can be easily located for future service 27 Setting the dip switch to activate on board buzzer To disable the audible alarm buzzer feature of the KE2 Adaptive Control the di...

Страница 14: ...d dFt diF OFFt Runt FrEF AU1 StA1 AU2 StA2 tS2 tOd d1 d2 d3 d4 d5 d6 d7 d8 d9 d10 d11 d12 dtSP drnt fdSP Fndt FndF Pdt HAO LAO tAd Adr Unt CLAL Schedule Defrost w Custom Defrost Per Day tS dtyP dFit d...

Страница 15: ...0V 208 240V StorageTemp 40 to 120 F 40 to 49 C OperatingTemp 40 to 120 F 40 to 49 C Display 4 digit 7 segment LED IP Rating IP65 Inputs 4 3 colored 15 temp sensors KE2 SKU 21151 2 dual purpose tempera...

Страница 16: ...ive cycles ECdF Excessive Defrost Controller has performed 11 consecutive defrost cycles without terminating on temperature PF Power Failure Indicates power has been off and just turned on only when d...

Страница 17: ...00 diS 23 59 diS d2 Start time of Defrost 2 0 00 diS 23 59 diS d3 Start time of Defrost 3 0 00 diS 23 59 diS d4 Start time of Defrost 4 0 00 diS 23 59 diS d5 Start time of Defrost 5 0 00 diS 23 59 diS...

Страница 18: ...lock d12 Defrost 12 Setpoint Start time of Defrost 12 when in defrosts per day dPd is custom CUSt based on 24 hour clock dAUt Defrost Auto Variable Defrost is in Automatic mode i e normal operation dE...

Страница 19: ...arm Offset LAO for the amount of time in theTempera ture Alarm Delay tAd NOAL No Alarm Alarm System is clear of alarms OFF System Off System State The system is currently not running OFFt Minimum Comp...

Страница 20: ...ay then press Use the up arrow and down ar row to set the time STEP 7 Press the button to save settings and return to the main screen room temp will be displayed Custom Defrost Setup The following ste...

Отзывы: