background image

KDK Company, Division of PES

Printed in Thailand
K25DSF2921 NET
T0913-0

K25DSF2NET

(The illustration shows an example of connecting for high 
power operation. For low power operation, connect cords 
according to the "Wiring Diagram" on page 11.)

Power cord 

Terminal

Terminal screw

Spring plate

Copper wire

X Section

It is required to use terminal (Not included) 
that complies IEC60998.

Connecting wiring

K28DSM2NET  K35DSM2NET  K40DSL2NET  K40DSH2NET  K45DST2NET

(The illustration shows an example of connecting for high power operation. For low power operation, connect cords according 
to the "Wiring Diagram" on page 11.)

Installation Instructions

Connecting wiring

1.Insert power cords into the terminal left-side holes as shown below figures.
2.Fasten each screws firmly, and check to pull softly and not to be pulled off or moved. 
3.After that, secure power cord with the nylon clamp and its screw so that all cords are not some tension pulled and pulled off.

After connection

Shut the terminal cover and tighten the screws.
At that time, carry out with much care against the 
terminal cover biting power cord.

Power
supply

Fan
body

The tip of the power cord which is not used must 
be insulated.

Protection tapes or covers for insulation

Terminal: For reference only
(Sold at parts stores.)

K40DTL2BET

  

K40DTH2BET  K45DTT2BET  K45DTH2BET

(The illustration shows an example of connecting for high power operation. For low power operation, connect cords according 
to the "Wiring Diagram" on page 11.)

Power cord 
(2 x 0.75mm

2

)

40

6

It is required to use terminal 
(Not included) that complies 
IEC60998.

Power cord treatment

X

Nylon clamp

Power cord: 
connected by electric technician

(from inside)

Note: Don't loosen 

these screws.

Power cord: 
connected by 
production

Terminal

Power cord 
(3 x 0.75mm

2

)

It is required to use terminal 
(Not included) that complies 
IEC60998.

Power cord treatment

Terminal

X

Nylon 
clamp

Power cord: 
connected by electric technician

(from inside)

Note: Don't loosen 

these screws.

Power cord: 
connected by 
production

1. Twist the power copper wire 

once and plug it into the 
terminal socket.

2. The power cord leads must not 

become separated or exposed, 
and should not come in contact 
with other cords.

3. Securely tighten the terminal 

screws.

40

6

(1)

Red

White

Black

unit : mm

unit : mm

Head Office : 4017, Takaki-cho, Kasugai, Aichi, Japan

Содержание K40DSH2NET

Страница 1: ...afety Precautions on page 2 4 prior to use K35DSM2NET K40DTL2BET Table of Contents Safety Precautions 2 4 Names and Dimensions of Component 5 Maintenance and Inspection 6 Periodic Check and Maintenanc...

Страница 2: ...all components and parts If they fall it may cause an injury When combustible gas leakage occurs open the windows to make air circulate When you start the fan a spark of the electrical contacts may c...

Страница 3: ...ls or if an electricity leakage occurs in it it may cause an electric shock Stop immediately the operation in case of any abnormality noise vibration smell and request for repair May cause unexpected...

Страница 4: ...or sucking the obstacle Don t operate with the wheel to which much dust has been adhered May cause wheel breakage or motor burnout Do not install the main body and indoor air supply entrance at the pl...

Страница 5: ...350 410 480 540 B 197 206 206 218 C 22 21 5 26 25 5 D 248 298 347 395 E 400 460 525 588 F 366 426 491 554 G 350 415 480 546 H M8 M8 M8 M10 I 32 32 32 34 J 9 9 9 11 Parts name Casing A Casing B Motor...

Страница 6: ...years Inspection Criteria Indication Maintenance Remarks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 Entire fan Update equipment 2 Casing Guide vanes 3 Wheel 5 Terminal Check noise and vibration by hearing...

Страница 7: ...f use operation time per day etc 5 Abnormal conditions from when and how it occurs 6 Handling air for general ventilation or for clean air and intended use symptom Insufficient air flow Excessive vibr...

Страница 8: ...25DSF2NET Single phase 220 240V 4 25 Hi 600 720 0 19 0 17 0 24 0 22 34 38 41 0 42 0 51 0 54 0 50 5 53 5 4 7 Lo 550 650 0 14 0 12 0 17 0 18 27 29 39 5 41 5 49 0 52 0 48 5 51 5 K28DSM2NET Single phase 2...

Страница 9: ...which requires water the place where steam generates the place where corrosive gas may generate and the place where chemicals are used Don t make a hole to the fan casing In the casing there are elec...

Страница 10: ...For power connecting removing or setting the terminal cover Install the exterior duct in over 1 100 declining slope toward outer side Make the access door opening to the side of power cord or termina...

Страница 11: ...ill stop Once the fuse blows the motor cannot restart itself that is it cannot rotate Locate and remove the cause of the error and replace the motor Note that an unstable or temporarily installed powe...

Страница 12: ...gainst the terminal cover biting power cord Power supply Fan body The tip of the power cord which is not used must be insulated Protection tapes or covers for insulation Terminal For reference only So...