background image

16

Humidity sensor detectible condition. (24CHRVB only) 

1  Humidity setting selector is stepless change between 45 %RH ~ 95 %RH.
2  The humidity detected by sensor may differ from the value on your hygrometer.
3  The product may turn on and off  cause by the unstable environment humidity, you can improve it 

  by adjusting the humidity setting selector. 

湿度传感器感应条件。(仅对于24CHRVB)

1 湿度传感器的设定范围为45%~95%。
2 湿度传感器感应湿度可能会和湿度计有出入。
3 根据环境的湿度变化,用户可以选择更换湿度传感器感应范围。

Motion sensor detectible condition. delay time is 

15 minutes. 

The following case may reduce sensitivity of the 

motion sensor.

- Little movement by occupants.

- A room temperature is close to body temperature. 

动作传感器感应条件。延时设定为15分钟。

以下情况可能会导致动作传感器感应不良。

  

用户非常轻微的活动。

  

室内温度非常接近人体温度。

OPERATION

运转

Fig.20 / 

图20

Fig.21 / 

图21

Humidity selector range from around 45% to 95%. 

Factory setting is around 85%. (Fig.20)

Humidity timer selector range of positions from 0 to 6h.

Factory setting is 1 hour. (Fig.20)

Humidity timer selector position OFF. (Fig.21)

Humidity sensor OFF follows motion sensor operation.

SELECTOR INDICATION 

 (24CHRVB only)

调节器指示

湿度传感器湿度感应范围为45%~95%。出厂预设为85%。(图20)

湿度传感器延时设定范围为0~6h,出厂预设为1h。
(图20)

湿度传感器延时设定为OFF。(图21)
当延时设定为OFF时,换气扇只有在动作传感器感应到用户运动时进行
运转。

OUTSIDE

Human
activity 

INSIDE

Fan
activity 

Stop

When motion 
is detected, 
fan runs 

Remains running
until 15 minntes 
has passed.  

The distance that motion can 

be detected is limited to 3 m. 

The field of view of the sensor 

is 90°.

(Room temperature is 25°.)

Sensor

3 m

Содержание 24CURB

Страница 1: ...could result in personal injury or property damage Please explain to users how to operate and maintain the product after the installation and this booklet should be presented to users Please retain t...

Страница 2: ...sion or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the supply cord is dama...

Страница 3: ...eated seriously that this may result in death or serious injury Warning This indication means Must be treated seriously that this may result in injury or physical damage The types of details to be obs...

Страница 4: ...product as the method which is not approved in the instruction Otherwise the product may fall down and it may cause injury Otherwise it may cause electric shock when there is any trouble or electric l...

Страница 5: ...ce of this product should be installed above 2 3 m from the floor after installation 2 3 m Do not reconstruct this product Otherwise it may cause damage to the product or injury Avoiding any accident...

Страница 6: ...llowing ductworks Ductwork 1 2 and 3 will increase the duct resistance and ductwork 4 will cause turbulence and airflow collisions These ductwork configurations may cause the product to operate under...

Страница 7: ...CCESSORIES The following attachments are enclosed in the packing box of ventilating fan Be sure to check if they are complete after unpacking and if anything is missed contact our After Sales Service...

Страница 8: ...f tapping screws of 4 2x20 Fig 4 4 2x20 2 4 Fig 2 2 2 Remove one hexagon screw that is fixed adaptor assembly and fan body then remove the adaptor assembly Fig 3 3 Fig 3 3 Fig 4 4 HOW TO INSTALL 1 Fan...

Страница 9: ...wer cord included earth of fan body to lead wire in accordance with the wiring diagram Fig 5 5 5 Make the power cord pass through the wooden frame push the fan body into wooden frame to fix the fan bo...

Страница 10: ...aptor assembly and fan body firmly with hexagon screw removed in step Fig 9 Fig 8 8 Fig 9 9 Fan body Hexagon screw Screwdriver Gloves Fig 10 10 Fig 11 11 Fig 12 12 8 Connect duct refer to page 12 2 Co...

Страница 11: ...ng should not be less than 20 mm Fig 14 Anchor bolt M8 M10 not supply refer to the following form Notice Suspension bracket must be made of metal with sufficient strength The screw length is 8 mm 8mm...

Страница 12: ...ly Suspend the duct from the ceiling so that no force is applied to the fan body Install the duct horizontally with a gradient downwards to the outside And the outlet of duct shall be located to avoid...

Страница 13: ...bration or noise Do not directly spray this product with water and other liquids Otherwise it may cause short circuitor electric shock Otherwise it may damage the product or cause fire Do not let wate...

Страница 14: ...plicable to living rooms washrooms and other places where the humidity is not too high Otherwise it may lead to short circuit or electric shock Never immerse blade or other resin parts in hot water ov...

Страница 15: ...t put into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 17 The Louver should be dry after cleaning 17 4 Clean the dirt of blades with vacuum cleaner Fig 18 18 5 Wipe the...

Страница 16: ...vement by occupants A room temperature is close to body temperature 15 OPERATION Fig 20 20 Fig 21 21 Humidity selector range from around 45 to 95 Factory setting is around 85 Fig 20 Humidity timer sel...

Страница 17: ...B 134 White Brown L Brown Blue N M O T O R M C Red Black Green Yellow Motion sensor Humidity sensor Humidity setting Timer Voltage Frequency Power consumption Air delivery Noise Static pressure Net we...

Страница 18: ...18 MEMO...

Страница 19: ...19 MEMO...

Страница 20: ...24CURB461A V0123 1063 Head office 4017 Takaki cho Kasugai Aichi Japan...

Отзывы: