Setting range
The following setting ranges are available for configuration of the unit:
Measuring voltage, primary
1 V to 9999 kV
Measuring voltage, secondary
100 V to 500 V
Measuring current, primary
1A to 99.99 kA
Measuring current, secondary
1 A to 5 A
Limits
depending on the configured trans-
former values
Current average time
1 to 15 minutes
Limits Cosφ
inductive 0.00 to capacitive 0.00
Frequency correction
Automatic - 50 Hz - 60 Hz
Limits frequency
00.00 Hz to 65 Hz
Limits
voltage harmonics
00.0% to 99.9%
Limits
current harmonics
0 to 300 A
Attenuation coefficient voltage
(display)
0 to 6
Attenuation coefficient current
(display)
0 to 6
Working pulse output
Active and reactive energy 0.001 to
9990 pulses per KWH or kvar
Energy pulse duration
30 to 990 milliseconds
Signaling relay ON-delay
0 to 254 seconds
Signaling relay shutdown delay
0 to 254 seconds
Measurement period synchronization Internal, KBR eBus, for tariff switching
Tariff switching
Internal, KBR eBus