O p e r a t i n g I n s t r u c t i o n s
|
megaSun Tower Optima
44
Technical Data
Ambient conditions
Installation site
In dry rooms (booths) with sufficient airing (intake and exhaust)
• max. Relative air humidity:
≤
70 %
• max. Room temperature:
≤
30 °C
• Minimum height of the room: 2270 mm
Electrical connection values
Protective class
IP 20
Mains voltage
400 V / ~ 3 N / 50 Hz
Wire cross section
5 x 2,5 mm
2
Ölflex
Fuses
Automatic fuse K-type (safety cut-out),
3-pole, 3x 25 A with residual current-operated circuit breaker (FI)
Nominal power
9900 W
Air discharge (optional feature)
Fan
Diameter 300 mm, Minimum capacity (exhaust air) 2000 m
3
/h
Exhaust-air hose
Diameter 300 mm
Unit data megaSun Tower Optima -
UV type 3 and 0.3 W/m
2
in compliance with EN 60335-2-27
Tubes
4x Collagen plus 1.2/36 - Item no.: 3230076124
48x ultimate 1902 R180W - Item no.: 3230076080
Equivalence key range: 180-R-(17-22)/(1,8-2,4)
Collagen booster
100x Rubin Collagen Booster
Dimensions in mm
(Height x Width x
Depth)
2180 +10 x 1400 +5 x 1405 +5 (closed)
2180 +10 x 1400 +5 x 1963 +5 (opened)
Weight
approx. 390 kg
Floor plate
max. load capacity
150 kg
MP3 player
• Supports SD cards up to 1-2 GB (SD) / 4-16 GB (SDHC)
• Supported file system (SD card): FAT16, FAT32
• Supported MP3 files: constant and variable bit rate, 96-320 Kbit/s
Содержание megaSun Tower Optima
Страница 1: ...OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 46: ...O p e r a t i n g I n s t r u c t i o n s megaSun Tower Optima 46 Remarks ...
Страница 47: ......