background image

 

Ethernet Switch User Manual

 

 

 

 

Manual-ESUG8P_Series_HW-Rev1112 
Copyright © KBC Networks Ltd. 

 Page 9 of 14 

www.kbcnetworks.com

 

2.7

 

DIP Switch Function

 

 

2.8

 

 LED Status 

LED 

Status 

Description 

 

P1 

 

ON 

Power is supplied to the unit 

 

OFF 

No power to the unit 

P2 

 

ON 

Power is supplied to the unit 

 

OFF 

No power to the unit 

P-Fail 

 

ON 

Power to P1 or P2 has failed 

 

OFF 

Power is functioning to both or none of the powered 
devices 

 

 

Ethernet RJ45 Port Status LED 

Each  RJ45  Ethernet  port  has  two  green  indicators.  The  lower  green  lamp  indicates 
whether power is being supplied to a PD and the upper green lamp indicates port link 
state. 

Green 
(lower) 
 

 

ON 

The port is supplying power to the powered device 

 

OFF 

There is no powered device attached or the power to the 
device has failed  

Green 
(upper) 
 

 

ON 

Effective  network  connection  has  been  established  for 
the port 

 

FLASH 

Data traffic is passing through the port 

 

OFF 

No effective network connection has been established for 
the port 

 
 

DIP-1

 

DIP-2 

Description 

 

OFF 

OFF 

Power failure relay alarm  & P-Fail disabled 

ON 

OFF 

P1 failure: relay alarm & P-Fail enabled  

OFF 

ON 

P2 failure: relay alarm & P-Fail enabled  

ON 

ON 

P1 or P2 failure: relay alarm & P-Fail enabled  

Содержание ESUG8P

Страница 1: ...Ethernet Switch User Manual ESUG8P ...

Страница 2: ...CKAGE CONTENTS 5 2 2 CONFIGURATIONS 5 2 2 1 Physical Connections 6 2 3 INSTALLATION METHOD 7 2 3 1 DIN Rail Mount 7 2 3 2 Wall mount 7 2 4 ETHERNET RJ45 CONNECTIONS 7 2 5 POWER CONNECTIONS 8 2 6 FAULT ALARM CONTACT 8 2 7 DIP SWITCH FUNCTION 9 2 8 LED STATUS 9 3 TROUBLESHOOTING 10 3 1 SELF TESTING 10 4 SYSTEM EXAMPLE 11 5 DIMENSIONS 11 6 WARRANTY 12 6 1 WARRANTY INFORMATION 12 6 2 CLASS A ITE 13 6 ...

Страница 3: ...oned industrial applications The units have redundant power supply terminals and an alarm output All copper ports are automatically configured and the plug and play design provides ease and speed of installation 1 1 1 ESUG8P The ESUG8P provides connectivity for up to eight 10 100 1000 RJ45 twisted pair copper ports with all eight ports capable of simultaneously supplying IEEE802 3at PoE Each port ...

Страница 4: ... 802 3 Transmission distance 100m PoE Physical port 8 x shielded RJ45 Standard IEEE 802 3at Power supplied per port 30W 50Vdc Electromagnetic compatibility Interference EN55022 Class A Immunity IEC61000 6 2 Power Input voltage 50 57Vdc Power consumption 8W no PoE 250W full load PoE Power supply Supplied separately Environmental Operating temperature 40 C 74 C 40 F 165 F Storage temperature 40 C 74...

Страница 5: ...th DIN rail mount 2 x Wall mount brackets with screws Pluggable terminal block Quick Start Guide Note A 50 57Vdc PSU is required but supplied separately Please contact you dealer or distributor if a part is missing or damaged 2 2 Configurations Products are available in either DIN rail or wall mount packages with the following configurations Product Type DIN Rail Wall mount ESUG8P ...

Страница 6: ...Ethernet Switch User Manual Manual ESUG8P_Series_HW Rev1112 Copyright KBC Networks Ltd Page 6 of 14 www kbcnetworks com 2 2 1 Physical Connections Front View ...

Страница 7: ...o the switch using the screws that have just been removed from the DIN rail mounting plate with a Phillips No 1 or No 2 screwdriver Position the unit on the required flat surface and secure with screws via the mounting plate holes Screws are not provided Attach copper cables as required Insert the male power block attached to the supplied in line PSU to the female power socket on the device and ti...

Страница 8: ...t number Connections 1 PWR2 2 PWR2 3 Fault alarm contact 4 Fault alarm contact 5 PWR1 6 PWR1 Note If only using one power source connect pin 1 to pin 5 and pin 2 to pin 6 otherwise the Power Fault Alarm will be lit 2 6 Fault Alarm Contact The fault alarm contacts are in the middle of the 6 pin screw block terminal on pins 3 4 An open circuit will occur if a power failure is detected Fig 2 2 Fault ...

Страница 9: ...cators The lower green lamp indicates whether power is being supplied to a PD and the upper green lamp indicates port link state Green lower ON The port is supplying power to the powered device OFF There is no powered device attached or the power to the device has failed Green upper ON Effective network connection has been established for the port FLASH Data traffic is passing through the port OFF...

Страница 10: ...ding to the power being supplied to the unit and the DIP switch selection see Section 2 7 If problems are encountered when using this Ethernet switch please check the following Verify that the correct power supply unit is being used this unit requires a 48Vdc supply Ensure that the correct cables are being used to construct your network o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 c...

Страница 11: ...HW Rev1112 Copyright KBC Networks Ltd Page 11 of 14 www kbcnetworks com 4 System Example Figure 4 1 ESUG8P Typical System Application 5 Dimensions WESII Client Power Injection Module Up to 7 IP Cameras IEEE 802 3at Compliant powered 8 Port Switch 5GHz ...

Страница 12: ... shock exposure to moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY c FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES 1 THE COST OF L...

Страница 13: ...ent This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful Interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense 7 Instruction of Disas...

Страница 14: ...630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com data delivered ...

Отзывы: