Ethernet Switch User Manual
Manual-ESUG8P_Series_HW-Rev1112
Copyright © KBC Networks Ltd.
Page 7 of 14
www.kbcnetworks.com
2.3
Installation Method
2.3.1
DIN Rail Mount
•
Remove all packaging material.
•
Attach the device to a DIN rail.
•
Attach copper cables as required.
•
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using a flathead screw driver.
See Section 2.7 for LED status.
2.3.2
Wall-mount
•
Remove all packaging material.
•
Unscrew the DIN rail mounting plate from the switch taking special care to
retain the 3 screws using a Phillips No.1 or No.2 screwdriver.
•
Attach the supplied wall mount plates to the switch using the screws that
have just been removed from the DIN rail mounting plate with a Phillips
No.1 or No.2 screwdriver.
•
Position the unit on the required, flat surface and secure with screws via the
mounting plate holes. Screws are not provided.
•
Attach copper cables as required.
•
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using a flathead screw driver.
See Section 2.7 for LED status.
2.4
Ethernet RJ45 Connections
Each RJ45 port is adaptive and supports auto MDI/MDI-X connection. They can be
connected by straight through or cross-over cables to terminal devices, servers, hubs or
other switches. Each switch supports IEEE802.3x and IEEE802.3ab so the optimum
transmission mode (either half-duplex or full-duplex) and data rate (10Mbps, 100Mbps
or 1000Mbps) will be selected automatically.