28
barrier)
15
Power interrupt, (emergency
battery mode)
K NO
16
Emergency battery is not
operative
K YES
17
Close position error
K
NO
18
Floor lock
YES
20
Jumper on power-print not
plugged
E YES
31
Closing hindrance special
F
YES
* The 24v power supply is switched off.
E The error is only identified during the setting-up procedure
F Fatal fault( The system is switched to manual)
K Error message remain as long as the mode error is pending.
NO.1-10
Basic kinds (Fatal fault) will cause the system interrupt.
No.11
It will cause the fatal fault during the adjusting. If occur the fault, the power is switched off
for 10 seconds and switched on for 0.6 second to check if voltage is normal, if not, repeat the
former action.
No.12
Without the inside position and lock position monitor: three attempts with reset, then
display the error.
With lock position monitor: The error will display as soon as it is checked.
No.13
Error can be checked only equipped with the inside position monitor and lock program
position
No.14
Error can be checked in the open position. If in the lock program position, the door will close at
slow speed upon 8 seconds, even if the fault remains.
No.15
Under the emergency battery-powered, the display will keep until the battery is exhausted.
( Example: lock-up program position)
No.16
Fault exists in adaptor, cable, safe and battery.
No.17
Display the door to be pushed off the closing position. For example, the installation center
seam is sealed, and checks the vehicle or the adjustment of the net width.
No.18
The floor lock fails to open.
No.31
Closing hindrance special
Eliminate the hindrance by pressing the emergency button, the switch lock or manual mode.
If there are several errors, the error first detected is the one displayed. The warning refers to the
warning output and is activated according to the error table(YES)
The LEDs on the electronic PCB ‘s indicate additional status and error displays which
complement the information supplied via PSA.
♦
Supply voltages
Internal electronics 5V(ON)
External voltage 24V(ON)
Motor power supply POWER(ON)