25
ON
Door closes in all program switch positions, the control panel power is shut. Opening via wake-up.
After each wake-up the door is closed. If the door is not yet closed, the above function applies
after the exhaustive discharge limit the emergency battery has been reached.
No.8 Sliding distance
OFF
Standard sliding distance
ON
When the open width is up to 180mm, the velocity will slow.
No.9 Active the PSA code lock, refer to chapter 5.1
ON
PSA code lock is effective, instead of the switch lock.
No.10 Keep open time
OFF
Keep- open time
starts at the moment that the door reaches the open position and all start signal
don’t come into use.
ON
Keep- open time
starts at the moment that the start signal deactivates. Example, in an interlock
application, the door may reverse or close when fail to reach the opening poison, after the person
has left the door area and provided that a short keep time. Under this circumstance, it is necessary
to use direction-sensitive radars
.
No.11 Winter/Summer
Winter/Summer actuation ON only makes sense for the sliding door, which is equipped with
direction-sensitive radars. The reduced opening width is canceled when bi-directional traffic. ( i.e.
radars inside and outside activated at the same time)
NO.12 Changing the direction of rotation of the drive unit 1
NO.13 Changing the direction of rotation of the drive unit 2.
No.14 Battery –powered mode
Refer to option ( Battery instruction)
Battery-powered emergency mode
By means of soft switch No. 14, a fixed direct current (21-30V) powers the input (X13). The soft
switch switches the charging electronics off, in order to prevent the current from flowing back
into the power network. Differing from the battery mode, the operation is not interrupted in the
Night of the program switch (No wake-up). However, the operation is interrupted if the voltage
drops below 19.5V during the standstill respectively below 16.5V when the door is moving.
No.15 Reset function
Strictly speaking, the soft switch 15 is not a real soft switch, but to set the reset function to the soft
switch lacking the default. If LED 32 is lit, which means that at least one soft switch No. (1….31)
is set. Press the button at the same time, all the soft switch value is neglected, so the function has a
general effect, it should be followed by a RESET.
No.16 Interlock impulse is memorized (Shut)
If the soft switch is ON, the start signal is memorized ( That is to say, only the opposite door has
been closed, the above command will be memorized)
No.17 Test program
Start the test program (The control unit generates automatically open command), all the start
signal is superior to the inner command. The reset operation will cause this function to be deleted.