12
Single-winged sliding door
CE
CE
Figure3.3
3
.
1
.
3 Installation of the sliding wings
1
.
On the running carriage screwed the sliding wings.
2
.
After completing the installation of the sliding wings, we should check the flexibility of the
counter-pressure roller (6) to make sure that the counter –pressure roller can be pushed
manually, when running carriage (2) is shifted, the pressure ruler (6) must be able to stop.
3
.
Adjust counter- pressure roller(6): slightly loose the Screw(7) about 1/2 circle, push the
screw along the slanting slots until the right position, and then screw it down. See Figure 3.4
Figure 3.4
3
.
1
.
4 The installation of stop piece on the carrier profile
3
.
1
.
4
.
1 Double-winged sliding door
CE
Figure 3.5
Each stop piece (25) include
:
2
pieces inner hexagon screw
Attention
: For both winged sliding door, when sliding sings closed, the stop pieces must touch
at the closing point CE (The closing pressure applied on the sliding wings must not exceed a
maximum value of 80N) For both winged sliding door, when sliding sings closed, the stop pieces
must touch at the closing point CE (The closing pressure applied on the sliding wings must not
exceed a maximum value of 80N)