SCROLL
ON/OFF
ON/OFF
OPTIONS
CURRENT STATE
DHW MODE
DISINFECT
HEAT MODE
SCROLL
SCROLL
OFF
ON
ON
ON
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
OPTIONS
CURRENT STATE
DHW MODE
DISINFECT
HEAT MODE
OFF
ON
ON
ON
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
1/2
OPTIONS
FROM
UNTIL
02-01-2019
16-01-2019
HOLIDAY
HOME
HOLIDAY
AWAY
SILENT
MODE
2/2
04:27
27-05-2019
sun
OK
CONFIRM
NO
YES
SCROLL
The ''HOLIDAY AWAY FUNCTION'' is on.
Do you want to turn off the holiday away function ?
SETTING
VALUE
HOLIDAY AWAY
on
DHW MODE
on
DISINFECT
on
HEAT MODE
on
FROM
02-01-2019
UNTIL
16-01-2019
21
6.4.2 HOLIDAY AWAY
If holiday away mode is enabled, the icon will be
displayed on the main interface.
The holiday away mode can prevent water from
freezing during holidays and start heating and water
heating before you are back home, thus guaranteeing
comfort and hot water at home.
Go to ''MENU'' > ''OPTIONS'' > ''HOLIDAY AWAY''.
Press ''OK''. The following page will appear:
For example:
Assume that you plan to leave home for a winter
vacation. If the current date is 2018-12-31 and you will
start your holiday two days later, the holiday start date
is 2019-01-02. If you have a two-week holiday and you
want to save energy and prevent freezing at home, you
can start holiday away mode as follows:
When DISINFECT is set to ON, and you set the
disinfection mode, the hydro module will automatically
perform disinfection at the set disinfection time prior to
the end of the holiday. For example, if FROM=2020-01-
02, UNTIL=2020-01-16, and disinfection time is set to
23:00 on Friday, disinfection begins from 23:00 on 2020-
01-10. If you do not set the disinfection mode, the hydro
module will forcedly enter disinfection mode at 22:00
on the day before the end of the holiday. If you do not
set the disinfection mode, the hydro module will begin
disinfection from 22:00 on 2020-01-16. After the hydro
module exits disinfection mode, the wired controller will
send the heat mode start-up command and DHW mode
start-up command to the hydro module.
TwoutS=TwoutS_H.A_H indicates the heat mode, while
TtankS=TtankS_H.A_DHW indicates the DHW mode.
TwoutS_H.A_H and TtankS_H.A_DHW are set on the
FOR SERVICEMAN interface of the wired controller.
Notes:
● In holiday mode, timer and weekly schedule are
invalid until the hydro module exits from holiday
mode.
● The CURRENT STATE option determines whether
to enable holiday mode. If CURRENT STATE = OFF,
HOLIDAY AWAY = OFF. If CURRENT STATE = ON,
HOLIDAY AWAY = ON.
● The multiple set point is invalid when the hydro
module operates in holiday mode.
● If disinfection mode is set in holiday mode, the hydro
module will enter the disinfection mode at 22:00 on
the day before the end of the holiday mode.
● In holiday mode, the weather temperature curve
is invalid until the hydro module exits from holiday
mode.
● In holiday mode, Preset Temp. is invalid until the
hydro module exits from holiday mode.
If you operate the wired controller in holiday mode, the
following prompt is displayed: