Kaysun KWF-140 HT ACS Скачать руководство пользователя страница 14

HEAT MODE

No. 

SCROLL

TIME

TEMP.

00:00

45

°C

2

00:00

45

°C

3

00:00

45

°C

1

1/2

MULTIPLE 

SET POINT

WEATHER 

TEMP. SET

PRESET 

TEMP.

HEAT MODE

No. 

SCROLL

TIME

TEMP.

00:00

45

°C

5

00:00

45

°C

6

00:00

45

°C

4

2/2

MULTIPLE 

SET POINT

WEATHER 

TEMP. SET

PRESET 

TEMP.

OK

SELECT

HEAT MODE

No. 

SCROLL

TIME

TEMP.

00:00

45

°C

2

00:00

45

°C

3

00:00

45

°C

1

1/2

MULTIPLE 

SET POINT

WEATHER 

TEMP. SET

PRESET 

TEMP.

OK

CANCEL

HEAT MODE

No. 

SCROLL

TIME

TEMP.

00:00

45

°C

2

00:00

45

°C

3

00:00

45

°C

1

1/2

MULTIPLE 

SET POINT

WEATHER 

TEMP. SET

PRESET 

TEMP.


04:27

sun

MAIN

SET

ON

45

°C

 

27-05-2019

04:27

No.

1
2
3
4
5
6

TIME

8:00

12:00
15:00
18:00
20:00
23:00

TEMP.

70°C
60°C
70°C
60°C
70°C
60°C

60°C

70°C

8:00 12:00 15:00 18:00 20:00 23:00

12

6 FUNCTIONS

6.1 HEAT MODE

In heat mode, PRESET TEMP.WEATHER TEMP.

SETMULTIPLE SET POINT are available.

6.1.1 PRESET TEMP.

PRESET TEMP. is used to set different desired water 

outlet temperatures at different times.

 

● PRESET TEMP. =PRESET TEMPERATURE

 

● The PRESET TEMP. function will be automatically 

disabled in the following conditions:
1) Timer is set.

2) Weekly schedule is set.

Take the following steps to enable PRESET TEMP.:

MENU

 > 

PRESET TEMPERATURE

 > 

PRESET TEMP.

 

Press 

OK

.

The following interface is displayed: 

use ''▲'', ''▼'', ''►'', ''◄'' to scroll and use ''▲'', ''▼'' to 

adjust the time and the temperature. When the cursor 

is on ''■'', as in the following page:

Press ''OK'', and the ''■'' becomes '' ''. The timer 1 is 

selected. Press ''OK'' again, and '' '' becomes ''■''. The 

timer 1 is unselected. 
use ''▲'', ''▼'', ''►'', ''◄'' to scroll and use ''▲'', ''▼'' to 

adjust the time and the temperature. Six temperatures 

can be set. For example: 
The time is 8:00 and temperature is 60

. If PRESET 

TEMP. is set as follows, the hydro module will operate 

according to the following curve.

Notes: 
1. When the multiple set point function is enabled, the 

PRESET TEMP. function is valid to space0 only.
2. If the hydro module is powered off, the preset 

temperature at the current time is invalid. The hydro 

module will be started at the time point where the next 

preset temperature is set.
3. When the timer function is valid, if you move the 

cursor to 

PRESET TEMP. 

and press the 

OK

 key, the 

following prompt is displayed:

Содержание KWF-140 HT ACS

Страница 1: ...r Before using your air conditioner please read this manual carefully and keep it for future reference The figure shown in this manual is for reference only and may be slightly different from the actu...

Страница 2: ...8 5 BASIC APPLICATION 5 1 Unlocking the Screen 08 5 2 Enabling Disabling Mode and Setting Temperature 09 6 FUNCTIONS 6 1 HEAT MODE 12 6 2 DOMESTIC HOT WATER DHW 15 6 3 SCHEDULE Function 17 6 4 OPTIONS...

Страница 3: ...e been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children must be supervised to ensure that they do not play with the product Unit are m...

Страница 4: ...45 04 27 MAIN ROOM Preset temp is unchanged Preset temp decreases Preset temp increases 27 05 2019 The anti freezing protection function has been enabled C C The heat recovery function has been enabl...

Страница 5: ...eat mode is classified into leaving water temperature control FOR SERVICEMAN Heat mode setting LEAVING WATER TEMP YES and room temperature control FOR SERVICEMAN Heat mode setting ROOM TEMP YES The le...

Страница 6: ...3 14 15 16 17 8 10 9 2 3 11 4 1 6 6 5 7 04 27 sun DHW TANK ON 45 C 04 Scenario 2 Only heat mode is available and the hydro module operates in room temperature control mode For more information please...

Страница 7: ...45 C 45 C Sets the desired water tank temperature ranging from 25 C to 80 C Sets the desired leaving water temperature ranging from 25 C to 80 C Indicates leaving water temperature control 05 Scenario...

Страница 8: ...on please read the Installation Manual and see Multiple Set Points on Page 14 in this document The settings of multiple set points do not affect the main interface The temperature of multiple set poin...

Страница 9: ...er query 5 The circulating pump and water tank temperature sensor should be connected to the master hydromodule To enable the group control function you need to set the DIP switch on the main board as...

Страница 10: ...nterface press MENU The following interface is displayed 5 BASIC APPLICATION 5 1 Unlocking the Screen If you do not operate the wired controller for a long time by default 120s which can be set on the...

Страница 11: ...nd disabled through the wired controller 5 2 1 Heat Mode There are two control methods for the heat mode Leaving water temperature control Room temperature control Leaving water temperature control In...

Страница 12: ...ually or through the timer function and weather temperature curve Take the following steps to set room temperature control mode MENU FOR SERVICEMAN HEAT MODE ROOM TEMP Set ROOM TEMP to YES Room temper...

Страница 13: ...7 27 05 2019 sun OK CONFIRM NO YES SCROLL DHW mode ON OFF function is locked Do you want to unlock it 11 5 2 2 DHW Mode Take the following steps to set the DHW mode MENU FOR SERVICEMAN DHW MODE Set DH...

Страница 14: ...TURE The PRESET TEMP function will be automatically disabled in the following conditions 1 Timer is set 2 Weekly schedule is set Take the following steps to enable PRESET TEMP MENU PRESET TEMPERATURE...

Страница 15: ...water outlet temperature control of heat mode If ROOM TEMP is set to YES on the wired controller the following information is displayed 6 1 2 WEATHER TEMP SET WEATHER TEMP SET WEATHER TEMPERATURE On...

Страница 16: ...mbient temperature H_weather_Twout the desired leaving water temperature when the outdoor temperature equals or rises above the high ambient temperature indicates the desired water outlet temperature...

Страница 17: ...required water temperature of multiple set point 2 4 The energy demand of space 1 is determined according to the thermostat 1 If thermostat 1 is on it indicates that there is an energy demand while i...

Страница 18: ...UNNING TIME is 30 minutes Set as follows Notes 1 If DHW MODE NON choose MENU DOMESTIC HOT WATER Press OK The following interface is displayed 2 If DISINFECT MODE NON on the FOR SERVICEMAN interface ch...

Страница 19: ...weekly schedule function is enabled the timer function will be disabled Use to scroll and use to adjust the time the mode and the temperature Move to press OK to select or unselect the timer is selec...

Страница 20: ...LE Timer and weekly schedule cannot take effect at the same time The time which is set later will take effect first If the weekly schedule is set the icon will be displayed on the main interface Choos...

Страница 21: ...ON ON 45 45 C C 19 6 3 4 CANCEL TIMER Go to MENU SCHEDULE CANCEL TIMER Press OK The following page will appear Use to move to YES Press OK to cancel the timer If you want to exit CANCEL TIMER press BA...

Страница 22: ...grade the capability of the hydro module You can set the hydro module to always operate in silent mode or to enter silent mode within a period of time On the main interface you can check whether silen...

Страница 23: ...e set disinfection time prior to the end of the holiday For example if FROM 2020 01 02 UNTIL 2020 01 16 and disinfection time is set to 23 00 on Friday disinfection begins from 23 00 on 2020 01 10 If...

Страница 24: ...cording to the schedule settings of the holiday mode without affecting the normal schedule If the holiday home mode is activated will display on the home page Go to MENU OPTIONS HOLIDAY HOME Press OK...

Страница 25: ...1 5 HB01 E1 17 32 03 06 2019 23 Use and to scroll and ON OFF to select LOCK or UNLOCK The heat DHW temperature can t be adjusted when the HEAT TEMP ADJUST DHW TEMP ADJUST is locked If you want to adj...

Страница 26: ...PERATION PARAMETERS OPERATION MODE COMPRESSOR FREQUENCY COMP RUN TIME 1 COMP RUN TIME 2 COMP RUN TIME 3 CURRENT SCROLL 2 6 80 Hrs 0 P 0 P 25 C 25 C 25 C OPERATION PARAMETERS COMP RUN TIME 4 EXPANSION...

Страница 27: ...V01 OPERATION PARAMETERS HYDRO BOX SOFTWARE CONTROLLER SOFTWARE OPERATION PARAMETERS HYDRO BOX OUTDOOR UNITS OK ENTER SCROLL SCROLL 1 3 0 HZ 0 kPa 0 kPa 0 C 25 C V01 OPERATION PARAMETERS ODU1_INV ODU1...

Страница 28: ...temperature TCS Desired discharge pipe pressure saturation temperature PC Discharge pipe pressure PE Suction pipe pressure TC Discharge pipe pressure saturation temperature TE Scution pipe pressure sa...

Страница 29: ...0 23 50 1 10 h min Temper 3 PRESET TEMP 3 45 25 80 1 C PRESET TEMP TIMER4 PRESET TEMP timer 3 on off 0 Off 1 On 0 0 1 1 PRESET TEMP TIME4 PRESET TEMP time 4 0 00 0 00 23 50 1 10 h min Temper 4 PRESET...

Страница 30: ...0 1 10 h min SILENT MODE TIMER ENDT 2 Silent mode timer end time 2 7 00 0 00 23 50 1 10 h min HOLIDAY AWAY CURRENT STATE Holiday away mode on off 0 Off 1 On 0 0 1 1 HOLIDAY AWAY DHW MODE Holiday away...

Страница 31: ...r hydro module operation is 16 A Speed 1 It indicates that the maximum current for hydro module operation is 15 A Speed 2 It indicates that the maximum current for hydro module operation is 14 A Speed...

Страница 32: ...l Ta 2 1 10 1 C WEATHER TEMP SETTING L_weather_Twout Water outlet temperature at low air temperature 70 25 80 1 C H_weather_Twout Water outlet temperature at high air temperature 45 25 80 1 C L_ODU_T4...

Страница 33: ...ry setting 8 Test run 9 Heat recovery mode setting 10 Power input limitation 11 SMART GRID 12 Hydro box addressing 1 DHW MODE 2 Disinfect mode 3 DHW priority 4 dTtankSH 5 TtankS_DI 6 t_DI_HIGHTEMP 7 t...

Страница 34: ...ove the electric heater from the sanitary hot water tank and immerse in a bucket or similar with lime removing product for 24 hours Indoor unit control box 1 Carry out a through visual inspection of t...

Страница 35: ...ature sensor error FA Suction pipe temperature sensor error F7 IDU same address error FC R410a loop liquid pipe temperature sensor error Fd R134a loop liquid pipe temperature sensor error F8 Room temp...

Страница 36: ...16123000001852 V A...

Страница 37: ......

Страница 38: ......

Отзывы: