7
Model
(Btu/h)
Amount of refrigerant
to be charged (kg)
maximum installation
height (m)
Minimum room
area (m²)
≤30000
≤2.048
1.8m
4
30000-48000
2.048-3.0
1.8m
8
>48000
>3.0
1.8m
9
Explanation of symbols displayed on the indoor unit or outdoor unit
(applicable to the unit adopts R32 Refrigerant only):
WARNING
This symbol shows that this appliance uses a flammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of fire.
CAUTION
This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
CAUTION
CAUTION
This symbol shows that information is available such as the operating
manual or installation manual.
WARNING
•
•
•
Appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation.
•
•
Appliance shall be installed, operated and stored in a room with a floor area larger than X m²,
installation of pipe-work shall be kept to a minimum X m² (Please see the following form).
1.
This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas
and the amount, please refer to the relevant label on the unit itself.
2.
Installation, service, maintenance and repair of this unit must be performed by a certified technician.
3.
Product uninstallation and recycling must be performed by a certified technician.
4.
If the system has a leak-detection system installed, it must be checked for leaks at least every 12
months.
5.
When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
Note about Fluorinated Gasses
Содержание KPD-105 DTN11
Страница 36: ...36 It comes from page 22 ...
Страница 40: ......