23
Scre
Table 8.1: Other World Regions
b. Using wire strippers, strip the rubber jacket
from both ends of the signal cable to reveal
approximately 15cm (5.9”) of wire.
c. Strip the insulation from the ends.
d. Using a wire crimper, crimp u-lugs on the
ends.
NOTE:
When connecting the wires, strictly
follow the wiring diagram found inside the
electrical box cover.
2. Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit, take
off the bolts from the maintenance board
and remove the protection board.
(See Fig. 8.1 and 8.2).
Indoor Unit Wiring
1. Prepare the cable for connection.
a. Using wire strippers, strip the rubber jacket
from both ends of the signal cable to reveal
about 15cm (5.9”) of the wire.
b. Strip the insulation from the ends of the
wires.
c. Using a wire crimper, crimp the u-lugs to
the ends of the wires.
2. Remove the cover of the electric control box
on your indoor unit.
3. Connect the u-lugs to the terminals.
Match the wire colors/labels with the labels
on the terminal block. Firmly screw the
u-l
ug of each wire to its corresponding
terminal. Refer to the Serial Number and
Wiring Diagram located on the cover of the
electric control box.
Control box
w
Fig. 8.1
Wiring diagram
Connective wiring diagram
Fig. 8.2
Magnetic ring
(if supplied and packed with the accessories)
3. Connect the u-lugs to the terminals
Match the wire colors/labels with the labels
on the terminal block. Firmly screw the u-lug
of each wire to its corresponding terminal.
4. Clamp down the cable with the cable clamp.
5. Insulate unused wires with electrical tape. Keep
them away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.
Fig. 8.3
Pass the belt through
the hole of the Magnetic
ring to fix it on the cable
Rated Current of
Appliance (A)
Nominal Cross-Sectional
Area (mm²)
£
6
2.5
6 - 10
2.5
10 - 16
2.5
16 - 25
2.5
25- 32
4
32 - 45
6
* See the end of this manual
Содержание KPD-105 DTN11
Страница 36: ...36 It comes from page 22 ...
Страница 40: ......