18
8.4.6 Requirements for power supply wiring
Fig. 8-9 Requirements of power supply wiring
Correct
Wrong
Power
distribution
transformer
Power
distribution
transformer
Manual
switch
Manual
switch
Power
380-415V
3N~50Hz
Power
380-415V
3N~50Hz
Fuses
Fuses
Uint
Uint
Lightning
arrester
Lightning
arrester
Surge
current
Grounding
wire
Grounding
wire
Grounding 3
Grounding 3
Grounding 2
Grounding 2
Grounding 1
Grounding 1
Building
• Do not connect the grounding wire of the lightning arrester to the unit shell. The grounding wire of the lightning arrester
and the power supply grounding wire must be configured separately.
NOTE
8.4.7 Requirements for power cord connection
L1 L2 L3 N
L1
L2 L3
N
L1 L2 L3 N
L1
L2 L3
N
Correct
Wrong
Fig. 8-10 Requirements for power cord connection