3.2 Air duct connection
1) Air inlet and outlet with duct. (A+B≤5m)
3) Air inlet connects to duct, air outlet without duct.(A≤5m)
A
Air outlet
Air inlet
B
A
Air outlet
Air inlet
Fig.3-5
Fig.3-3
It is recommended to install unit by this way in summer
that could charge fresh air into room.
2) Air inlet without duct, air outlet connects to duct.
˄
A≤5m
˅
4) Duct Description
A
Air outlet
Table3-1
Air inlet
Round
duct
Rectangle
duct
Duct
Dimension(mm)
160
160X160
≤2
Straight-line pressure
drop (Pa/m)
≤2
Straight-line
length (m)
≤5
≤5
Bent pressure
drop(Pa)
≤2
≤5
≤2
≤5
Bent’s qty.
Fig.3-4
It is recommended to install unit by this way in the winter
where there is other heat source in the room.
Installation & Owner‘s Manual
5