background image

  

 

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabili- 

ties, or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the 

appliance by a person responsible for their safety. Children 

should be supervised to ensure that they do not play with the 

appliance. 

  Do not turn off the power supply. 

System will stop or restart heating automatically. A continuous  

power supply for water heating is necessary, except service and  

maintenance.  
If the unit has not been used for a long period of time(2 weeks or  

more), hydrogen gas will be produced in the water piping system. 
Hydrogen gas is extremely flammable. To reduce the risk of injury  

under these conditions, it is recommended that open the hot water  

tap for several minutes at the kitchen sink before using any  

electrical appliance connected to the hot water system. When  

hydrogen is present, there will probably be an unusual sound such  

as air escaping through the pipe as the water begins to flow. There  

should be no smoking or open flame near the tap at the time it is  

open.  

If the supply cord is damaged, it must be replaced by the 

manufacturer or its service agent or a similarly qualified 

person. 

DISPOSAL                                                                   Do not 
dispose this product as 

unsorted municipal waste. Collection of such waste 

separately for special treatment is necessary. 

Do not dispose of electrical appliances as unsorted 

municipal waste, use separate collection facilities. 

Contact your local government for information 

regarding the collection systems available. 

2.  BEFORE INSTALLATION 

If electrical appliances are disposed of in landfills or dumps, 

hazardous substances can leak into the groundwater and get 

into the food chain, damaging your health and well-being. 

2.1  Unpacking 

2.1.1  Accessories 

Table2-1 

CAUTION 

Accessory Name 

Qty.  Sharp 

Purpose 

Owner’s & Installation 
Manual 

Installation and use instruction 

This manual 

The earthing pole of socket must be grounded well, make 
sure that power supply socket and plug are dry enough and 
connected tightly. 

Prevent water from  

flowing backwards  

One Way Valve 

How to check the power supply socket and plug are qualified? 
Turn on power supply and keep the unit running for a half 
hour, then turn off power supply and plug out, check whether 
the socket and plug is hot or not. 

Pipe

˄

short

˅

for  

Discharge condensated water 

Discharge condensated water 

water condensation 
Drain pipe for  

water condensation 

Before cleaning, be sure to stop the operation and turn the 
breaker off or pull out the power plug. 
Otherwise, an electric shock and injury may be caused. 

Filter 
Ring 


To connect to a remote  

shutdown switch 

White wires 

Water temperature over 50

ć

 

can cause severe burns instantly 

2.1.2  How to transport 

 or serious injuries from scalds. 
Children, disabled and elderly 

are at highest risk of being 

scalded. Feel water before 
bathing or showering. 
Water temperature limiting 
valves are recommended. 

1)  In order to avoid scratch or deformation 

of the unit surface, apply guard boards 
to the contacting surface. 
No contact of fingers and other things 
with the vanes. 
Don’t incline the unit more than 75° 
in moving, and keep it vertical when 
installing. 

2)  This unit is heavy, it need to be carried by two or more persons, 

otherwise might cause injury and damage. 

>75° 

Gradient limit>75° 

Do not operate the unit with a wet hand. 
An electric shock may be caused. 

The installation height of power supply should be over 1.8m, if 
there is any water spattered, separate the power supply from 
water. 

2.2  Location requirements 

1)  Enough space for installation and maintenance shall be  

preserved.     

A one-way valve must be installed on the water inlet side, 
which is available from accessories, see manual "accessories" 
part. 

2)  The air inlet and outlet should be free from obstacles and strong  

wind. 

3)  The base surface should be flat, surface should be inclined no  

more than 2°and able to bear the weight of the unit and suitable  

for installing the unit without increasing noise or vibration. 

It’s normal if some water drops from the hole of PT valve 
during operation. But, if there is a great amount of water, call 
your service agent for instructions. 

4)  The operation noise and air flow expelled shall not affect  

neighbours 

After a long term use, check the unit base and fittings. 

If damaged, the unit may sink and result in injury. 

5)  No flammable gas is leaked nearby. 

6)  It is convenient for piping and wiring. 

Arrange the drain pipe to ensure smooth draining. 

Improper drainage work may cause wetting of the building,  

furniture etc. 

7)  If it is installed in indoor space, it might cause indoor temp  

decreased and noise. Please take preventive measures for this. 

Do not touch the inner parts of the controller. 

Do not remove the front panel. Some parts inside are  

dangerous to touch, otherwise a machine malfunction may be  

caused. 

8)  If the unit has to be installed on a metal part of building, make  

sure the well electric insulation which should meet the relevant  

local electric standard.  

Installation & Owner‘s Manual 

Содержание COMPAK KHP 15/190 ACS1

Страница 1: ...S MANUAL ALL IN ONE Type Air source Heat Pump Water Heater COMPAK KHP 15 190 ACS1 Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it fo...

Страница 2: ...MD14IU 029DW 202000172619...

Страница 3: ...being The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram An all pole disconnection device which has at least 3mm separatio...

Страница 4: ...Water Outlet Cover Electric Heater Electric Heater Water Inlet Drain Pipe When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name NOTE Al...

Страница 5: ...ta will show more details You may be killed or seriously injured DANGER immediately if you don t obey instructions WARNING The unit must be earthed effectively A creepage breaker must be installed adj...

Страница 6: ...water condensation Drain pipe for water condensation Before cleaning be sure to stop the operation and turn the breaker off or pull out the power plug Otherwise an electric shock and injury may be cau...

Страница 7: ...Hot spring area where corrosive gases exist e g sulphide gas Factories where the power voltage fluctuates seriously Inside a car or cabin The water heater must be located in a space 15m and must have...

Страница 8: ...using the tank When water flow smoothly out from water outlet pipe tap water outlet the tank is full turn off all valves and check pipeline to make sure there is no any leakage CAUTION 4 If the inlet...

Страница 9: ...could charge fresh air into room 2 Air inlet without duct air outlet connects to duct A 5m 4 Duct Description A Air outlet Table3 1 Air inlet Round duct Rectangle duct Duct Dimension mm 160 160X160 2...

Страница 10: ...It is recommended to install the unit in the indoor space it is not allow to install the unit at the rainy space Fig 3 8 D Rain Filter Owner should install the filter by self and the mesh size is abou...

Страница 11: ...Electric Heater Item Content Fan capacity Terminal base Transformer Connected wires inside of the tank Zero phase electricity mutual inductor AC mutual inductor Relay connecting wires Relay Without D...

Страница 12: ...ion Solar Input 300L ON OFF SW2 Factory Setting for 190L 300L Model Selection High Pressure Switch Transformer Panel Display Panel Display T5L Lower T5U Upper T3 Evaporator T4 Ambient Th Comp Tp Comp...

Страница 13: ...ration 1 GND Wiring size and connections comply with all local applicable codes and the requirements of this manual Power Cable with Creepage Breaker Water heater and electrical supply are properly gr...

Страница 14: ...installation 8 Sufficient inlet water pressure between 0 15MPa and 0 65MPa Water out Fig 4 1 4 2 2 About Running CAUTION 1 System Structure Figure Unit has two kinds of heat sources heat pump compress...

Страница 15: ...se manually activate E heater Restart After a Long Term Stop When the unit is restarted after a long term stop trail running included it is normal that outlet water is unclean Keep the tap on and the...

Страница 16: ...pressor Last error code ON OFF 8 Previous 1st error or protection code 9 Fig 5 1 Previous 2nd t error or protection code 10 11 5 2 Display Explanation Software number SET SET CLOCK DAY 1 2 ON 3 4 ON 5...

Страница 17: ...s celsius will be lightened will show celsius degree If setting temperature unit as Fahrenheit will be lightened will show Fahrenheit degree Press for 10sec it will change between and No Icon Descript...

Страница 18: ...ally ON 1 The moment of Manually ON has priority 2 The moment of Timer OFF has priority Set the hour value of timer Confirm the hour value of timer Then the minute value of timer will flash slowly CAN...

Страница 19: ...ess button disinfect clock setting Then icon flash and icon will be lightened for 3sec to enter will Press button for and the hour value of clock will flash slowly 1s or no button operation for 30s th...

Страница 20: ...unt of hot water can be tapped A Because the upper water sensor is located on the upper 1 4 tank when tapping hot water out it means there is at least 1 4 tank of hot water available 1 Public water su...

Страница 21: ...out clock menmory so it is needed to reset clock when power put on again EF Clock chip error If necessary contact a qualified person to service the unit Ed P2 E EPROM chip error Contact a qualified pe...

Страница 22: ...Operate the hander of PT valve to ensure that waterways are clear Clean the air filter every month in case of any inefficiency on the heating performance In terms of the filter set in air inlet direct...

Страница 23: ...adjustable Water side exchanger Inlet pipe Dia Outlet pipe Dia Drain pipe Dia PT valve Dia The test conditions Ambient temperature 15 12 C DB WB Water temperature from 15 C up to 45 C Installation Ow...

Страница 24: ......

Отзывы: