About Fluorinated Gasses
- This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and the amount,

please refer to the relevant label on the unit itself. Compliance with national gas regulations shall be observed.
- Installation, service, maintenance and repair of this unit must be performed by a certified technician.
- Product uninstallation and recycling must be performed by a certified technician.
- If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months. When

the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.

Do not install the unit in the following places:
- Where there is mist of mineral oil, oil spray or vapors. Plastic parts may deteriorate, and cause them to come loose 

or water to leak.
- Where corrosive gases (such as sulphurous acid gas) are produced. Where corrosion of copper pipes or soldered

parts may cause refrigerant to leak.
- Where there is machinery which emits electromagnetic waves. Electromagnetic waves can disturb the control

system and cause equipment malfunction.
- Where flammable gases may leak, where carbon fiber or ignitable dust is suspended in the air or where volatile

flammables such as paint thinner or gasoline are handled. These types of gases might cause a fire.
- Where the air contains high levels of salt such as near the ocean.
- Where voltage fluctuates a lot, such as in factories.
- In vehicles or vessels.
- Where acidic or alkaline vapors are present.
This appliance can be used by children 8 years old and above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they are supervised or given instruction on using the unit in a 

safe manner and understand the hazards involved. Children should not play with the unit. Cleaning and user 

maintenance should not be done by children without supervision.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufaturer or its service agent or a similarly qualified 

person.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste seperatelly for 

special treatment is necessary. Do not dispose of electrical appliances as municipal waste, use seperate collection 

facilities. Contact your local goverment for information regarding the collection systems available. If electrical 

appliances are disposed of in landfills or dumps, hazardous substance can leak into the groudwater and get into the 

food chain, damaging your health and well-being.
The  wiring must be performed by professional technicians in accordance with national wiring regulation and this 

circuit diagram. An all-pole disconnection device which has at least 3mm seperation distance in all pole and a 

residualcurrent device(RCD) with the rating not exceeding 30mA shall be incorporated in the fixed wiring according 

to the national rule.
Confirm the safety of the installation area ( walls, floors, etc. ) without hidden dangers such as water, electricity, and 

gas.Before wiring/pipes.
Before installation , check whether the user's power supply meets the electrical installation requirements of unit ( 

including reliable grounding , leakage , and wire diameter electrical load, etc. ). If the electrical installation 

requirements of the product are not met, the installation of the product is prohibited until the product is rectified.
When installing multiple air conditioners in a centralized manner, please confirm the load balance of the three-phase 

power supply, and multiple units are prevented from being assembled into the same phase of the three-phase power 

supply.
Product installation should be fixed firmly, Take reinforcement measures, when necessary.

Содержание Aquantia R-32 PRO

Страница 1: ...please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL Aquantia R 32 PRO Mural Bibloc Outdoor Unit KHP BI 4 DVR2 KHP BI 6 DVR2 KHP BI 8 DVR2 KHP BI 10 DVR2 KHP...

Страница 2: ......

Страница 3: ...Installation requirements Drain hole position Installation space requirements 6 1 6 2 6 3 6 4 6 SAFETY PRECAUTIONS ACCESSORIES BEFORE INSTALLATION IMPORTANT INFORMATION FOR THE REFRIGERANT INSTALLATIO...

Страница 4: ...IONS ON REFRIGERANT LEAKAGE 25 26 34 28 28 28 28 28 28 Protection equipment About power cut Heating capcity Compressor protection feature Cooling and heating operation Features of heating operation De...

Страница 5: ...stallation NOTE Please remove the noise insulation cover of the compressor first Please make sure the transportation support had be removed It will cause heat pump abnormal vibration and noise if runn...

Страница 6: ...ded into the following types They are quite important so be sure to follow them carefully Meanings of DANGER WARNING CAUTION and NOTE symbols Indicates an imminently hazardous situation which if not a...

Страница 7: ...ire Make sure all wiring is secure Use the specified wires and ensure that terminal connections or wires are protected from water and other adverse external forces Incomplete connection or affixing ma...

Страница 8: ...ed Children should not play with the unit Cleaning and user maintenance should not be done by children without supervision Children should be supervised to ensure that they do not play with the applia...

Страница 9: ...ation Fittings Water outlet connection pipe assembly Before installation Be sure to confirm the model name and the serial number of the unit Handling 3 BEFORE INSTALLATION Energy label 1 05 1 Handle t...

Страница 10: ...GERANT This product has the fluorinated gas it is forbidden to release to air Refrigerant type R32 Volume of GWP 675 GWP Global Warming Potential Factory charged refrigerant volume in the unit Refrige...

Страница 11: ...sive atmosphere Places where servicing space can be well ensured Places where the units piping and wiring lengths come within the allowable ranges Places where water leaking from the unit cannot cause...

Страница 12: ...avoild direct sunlight so that it is not influenced by the sun s heat otherwise protection may be possible to the unit Make sure there is enough space to do the installation Set the outlet side at a r...

Страница 13: ...ng the operation In accordance with the foundation drawing in the figure fix the unit securely by means of foundation bolts Prepare four sets each of 10 Expansion bolts nuts and washers which are read...

Страница 14: ...nit with the base electric heater CAUTION Drain hole This drain hole is covered by rubber plug If the small drain hole can not meet the drainage requirements the big one can be used at the same time 5...

Страница 15: ...er row Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 150 600 1 2 H B2 A B1 C H 500mm 500mm 1 2 H B2 A B1 C H Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 300 600 11 7 INSTALL THE CONNECTING PIPE 7 1 Refr...

Страница 16: ...D C 7 3 Heat insulation In order to avoid the release of cold or heat from the connecting pipeline to the external environment during the operation of the equipment please take effective insulation m...

Страница 17: ...R32 R32 4 6kW MODEL 15 9 9 52 7 4 Connecting method Indoor Unit Outdoor Unit H Gas side Liquid side Flaring Flaring Flaring Flaring 4 16 kW 30m 20m Figure 7 5 4 16kW outdoor unit Indoor unit Models Ma...

Страница 18: ...valves 2 The airtight testing should never use any oxygen flammable gas or poisonous gas 7 7 Air purge with vacuum pump 1 Using vacuum pump to do the vacuum never using refrigerant to expel the air 2...

Страница 19: ...heating of the capacitor due to high frequency waves Never install a phase advancing capacitor as it could lead to an accident Secure the electrical wiring with cable ties as shown in figure so that...

Страница 20: ...wire diameters should be selected according to the national wiring regulation 2 Select circuit breaker that having a contact separation in all poles not less than 3 mm providing full disconnection whe...

Страница 21: ...NOTE A B C D E F 8 5 To finish the outdoor unit installation insulate and fix the refrigerant piping and interconnection cable as follows A Gas pipe B Gas pipe insulation C Finishing tipe D Liquid pip...

Страница 22: ...electrical parts 4 6kW 8 10 12 14 16kW WARNING Cut off all power supply i e unit power supply and backup heater and domestic hot water tank power supply if applicable before removing doors 1 Parts ins...

Страница 23: ...19 The picture is for reference only please refer to the actual product NOTE PCB A PCB B 12 14 16kW 1 phase PCB A PCB B PCB C 12 14 16kW 3 phase Back PE1 PE2 CN30...

Страница 24: ...B B CN32 Input port L for rectifier bridge CN501 Input port N for rectifier bridge CN502 1 2 3 CN20 CN19 CN32 CN502 CN23 CN6 CN501 4 8 5 6 7 9 10 1 2 3 4 5 Assembly unit Assembly unit Coding Coding 6...

Страница 25: ...play DSP1 Port for chassis electrical heating tape CN16 optional Port for compressor eletric heating tape 1 CN7 Port for 4 way value CN6 Port for SV6 value CN5 Port for compressor eletric heating tape...

Страница 26: ...unit Assembly unit Coding Coding 9 10 11 12 13 8 Compressor connection port W CN19 Compressor connection port U CN17 Power Input port L3 CN15 Power Input port L1 CN16 Power Input port L2 CN7 Port for...

Страница 27: ...und wire CN38 Port for eletric heating tape2 CN7 Port for 4 way value CN18 Reserved CN11 Port for outdoor ambient temp sensor and condenser temp sensor CN9 8 10 11 12 13 Port for eletric heating tape1...

Страница 28: ...er ltering L2 L2 Power ltering L3 L3 3 PCB C filter board PCB C 3 phase 12 14 16kW PE1 PE2 PE3 CN202 CN201 CN200 CN203 CN204 CN205 CN206 CN212 CN211 CN8 CN213 CN214 CN30 2 5 4 3 6 13 12 7 8 9 10 11 14...

Страница 29: ...ly Install leak alarm facility related to mechanical ventilator if you can not regularly ventilate 2 Requirments for charge limits in unventilated areas The maximum refrigerant charge in appliance sha...

Страница 30: ...s filled of leakage refrigerant All refrigerant has leaked out 8 10 12 14 16 kW Fig 11 2 Fig 11 3 12 TURN OVER TO CUSTOMER The owner s manual of indoor unit and owner s manual of outdoor unit must be...

Страница 31: ...ed object The remote controller may be damaged Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Do not use the heat pump for other purposes In order to avoid...

Страница 32: ...2 About power cut If power is cut during operation stop all the operation immediately Power comes again If the auto restart function is set on then the unit will auto restart Mishandling in operation...

Страница 33: ...T4 error 1 The Th sensor connector is loosen Re connect it 2 The Th sensor connector is wet or there is water in remove the water make the connector dry Add waterproof adhesive 3 The Th sensor failure...

Страница 34: ...or Pressure sensor failure Refer to P0 Low pressure protection in cooling Pe 0 6 occurred 3 times in an hour Refer to H6 H6 displayed 10 times in 2 hours 1 The EEprom parameter is error rewrite the EE...

Страница 35: ...on High pressure switch protection 1 The same reason to P1 2 TW_out temp sensor is loosen Reconnect it 3 T1 temp sensor is loosen Reconnect it 4 T5 temp sensor is loosen Reconnect it High discharge te...

Страница 36: ...And if those IGBT are OK which means the inverter board is OK power form rectifier bridge is not correct check the bridge Same method as IGBT disconnect the power check those dioxides are damaged or n...

Страница 37: ...protection MCE malfunction 1 Check the Heat pump system pressure 2 Check the phase resistance of compressor 3 Check the U V W power line connection sequence between the inventer board and the compres...

Страница 38: ...quid side Drain connection Max piping length 30m Max differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin...

Страница 39: ...differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin coil Refrigerant R32 Weight Connections 9 52 220 24...

Страница 40: ...he period that the work is carried out The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere 8 Checks to the refrigeration equipment Wh...

Страница 41: ...sed the system shall be vented down to atmospheric pressure to enable work to take place This operation is absolutely vital if brazing operations on the pipe work are to take place Ensure that the out...

Страница 42: ...or decommissioning it is recommended good practice that all refrigerants are removed safely When tranferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are...

Страница 43: ...pansion Valve Single way electromagnetic valve Filter Discharge temperature sensor Outdoor temperature sensor Outdoor exchanger sensor Stop valve gas Stop valve liquid High Pressure Switch Low Pressur...

Страница 44: ...r reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supply volatge 230VAC NOTE ANNEX B To install the E heating tape at the drainage outlet b...

Страница 45: ...ase 12 14 16kW 3 phase XT3 To the heating tape of drainage outlet A The picture is for reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supp...

Страница 46: ...16125300002360 V4 0...

Страница 47: ......

Страница 48: ......

Отзывы: