03

Before touching electric terminal parts, turn off power switch.
When service panels are removed, live parts can be easily touched by accident.
Never leave the unit unattended during installation or servicing when the service panel is removed.
Do not touch water pipes during and immediately after operation as the pipes may be hot and could burn your 

hands. To avoid injury, give the piping time to return to normal temperature or be sure to wear protective gloves.
Do not touch any switch with wet fingers. Touching a switch with wet fingers can cause electrical shock.
Before touching electrical parts, turn off all applicable power to the unit.

DANGER

Tear apart and throw away plastic packaging bags so that children will not play with them.Children playing 

with plastic bags face danger of suffocation.
Safely dispose of packing materials such as nails and other metal or wood parts that could cause injuries.
Ask your dealer or qualified personnel to perform installation work in accordance with this manual. Do not install the 

unit yourself. Improper installation could result in water leakage, electric shocks or fire
Be sure to use only specified accessories and parts for installation work. Failure to use specified parts may result in 

water leakage, electric shocks, fire, or the unit falling from its mount.
Install the unit on a foundation that can withstand its weight. Insufficient physical strength may cause the equipment 

to fall and possible injury.
Perform specified installation work with full consideration of strong wind, hurricanes, or earthquakes. Improper 

installation work may result in accidents due to equipment falling.
Make certain that all electrical work is carried out by qualified ersonnel according to the local laws and regulations 

and this manual using a separate circuit. Insufficient capacity of the power supply circuit or improper electrical 

construction may lead to electric shocks or fire.
Be sure to install a ground fault circuit interrupter according to local laws and regulations. Failure to install a ground 

fault circuit interrupter may cause electric shocks and fire.
Make sure all wiring is secure. Use the specified wires and ensure that terminal connections or wires are protected 

from water and other adverse external forces. Incomplete connection or affixing may cause a fire.
When wiring the power supply, form the wires so that the front panel can be securely fastened. If the front panel is 

not in place there could be overheating of the terminals, electric shocks or fire.
After completing the installation work, check to make sure that there is no refrigerant leakage.
Never directly touch any leaking refrigerant as it could cause severe frostbite.Do not touch the refrigerant pipes 

during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the condition of 

the refrigerant flowing through the refrigerant piping, compressor and other refrigerant cycle parts. Burns or frostbite 

are possible if you touch the refrigerant pipes. To avoid injury, give the pipes time to return to normal temperature 

or, if you must touchthembe sure to wear protective gloves.
Do not touch the internal parts (pump, backup heater, etc.) during and immediately after operation. Touching the 

internal parts can cause burns. To avoid injury, give the internal parts time to return to normal temperature or, if you 

must touch them, be sure to wear protective gloves.

WARNING

Ground the unit.
Grounding resistance should be according to local laws and regulations. 
Do not connect the ground wire to gas or water pipes, lightning conductors or telephone ground wires. 
Incomplete grounding may cause electric shocks.
- Gas pipes

Fire or an explosion might occur if the gas leaks.

- Water pipes

Hard vinyl tubes are not effective grounds.

- Lightning conductors or telephone ground wires

Electrical threshold may rise abnormally if struck by a lightning

bolt.
Install the power wire at least 3 feet (1 meter) away from televisions or radios to prevent interference or noise. 

(Depending on the radio waves, a distance of 3 feet (1 meter) may not be sufficient to eliminate the noise.)
Do not wash the unit. This may cause electric shocks or fire. The appliance must be installed in accordance with 

national wiring regulations. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent 

or similarly qualified persons in order to avoid a hazard.

CAUTION

Содержание Aquantia R-32 PRO

Страница 1: ...please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL Aquantia R 32 PRO Mural Bibloc Outdoor Unit KHP BI 4 DVR2 KHP BI 6 DVR2 KHP BI 8 DVR2 KHP BI 10 DVR2 KHP...

Страница 2: ......

Страница 3: ...Installation requirements Drain hole position Installation space requirements 6 1 6 2 6 3 6 4 6 SAFETY PRECAUTIONS ACCESSORIES BEFORE INSTALLATION IMPORTANT INFORMATION FOR THE REFRIGERANT INSTALLATIO...

Страница 4: ...IONS ON REFRIGERANT LEAKAGE 25 26 34 28 28 28 28 28 28 Protection equipment About power cut Heating capcity Compressor protection feature Cooling and heating operation Features of heating operation De...

Страница 5: ...stallation NOTE Please remove the noise insulation cover of the compressor first Please make sure the transportation support had be removed It will cause heat pump abnormal vibration and noise if runn...

Страница 6: ...ded into the following types They are quite important so be sure to follow them carefully Meanings of DANGER WARNING CAUTION and NOTE symbols Indicates an imminently hazardous situation which if not a...

Страница 7: ...ire Make sure all wiring is secure Use the specified wires and ensure that terminal connections or wires are protected from water and other adverse external forces Incomplete connection or affixing ma...

Страница 8: ...ed Children should not play with the unit Cleaning and user maintenance should not be done by children without supervision Children should be supervised to ensure that they do not play with the applia...

Страница 9: ...ation Fittings Water outlet connection pipe assembly Before installation Be sure to confirm the model name and the serial number of the unit Handling 3 BEFORE INSTALLATION Energy label 1 05 1 Handle t...

Страница 10: ...GERANT This product has the fluorinated gas it is forbidden to release to air Refrigerant type R32 Volume of GWP 675 GWP Global Warming Potential Factory charged refrigerant volume in the unit Refrige...

Страница 11: ...sive atmosphere Places where servicing space can be well ensured Places where the units piping and wiring lengths come within the allowable ranges Places where water leaking from the unit cannot cause...

Страница 12: ...avoild direct sunlight so that it is not influenced by the sun s heat otherwise protection may be possible to the unit Make sure there is enough space to do the installation Set the outlet side at a r...

Страница 13: ...ng the operation In accordance with the foundation drawing in the figure fix the unit securely by means of foundation bolts Prepare four sets each of 10 Expansion bolts nuts and washers which are read...

Страница 14: ...nit with the base electric heater CAUTION Drain hole This drain hole is covered by rubber plug If the small drain hole can not meet the drainage requirements the big one can be used at the same time 5...

Страница 15: ...er row Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 150 600 1 2 H B2 A B1 C H 500mm 500mm 1 2 H B2 A B1 C H Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 300 600 11 7 INSTALL THE CONNECTING PIPE 7 1 Refr...

Страница 16: ...D C 7 3 Heat insulation In order to avoid the release of cold or heat from the connecting pipeline to the external environment during the operation of the equipment please take effective insulation m...

Страница 17: ...R32 R32 4 6kW MODEL 15 9 9 52 7 4 Connecting method Indoor Unit Outdoor Unit H Gas side Liquid side Flaring Flaring Flaring Flaring 4 16 kW 30m 20m Figure 7 5 4 16kW outdoor unit Indoor unit Models Ma...

Страница 18: ...valves 2 The airtight testing should never use any oxygen flammable gas or poisonous gas 7 7 Air purge with vacuum pump 1 Using vacuum pump to do the vacuum never using refrigerant to expel the air 2...

Страница 19: ...heating of the capacitor due to high frequency waves Never install a phase advancing capacitor as it could lead to an accident Secure the electrical wiring with cable ties as shown in figure so that...

Страница 20: ...wire diameters should be selected according to the national wiring regulation 2 Select circuit breaker that having a contact separation in all poles not less than 3 mm providing full disconnection whe...

Страница 21: ...NOTE A B C D E F 8 5 To finish the outdoor unit installation insulate and fix the refrigerant piping and interconnection cable as follows A Gas pipe B Gas pipe insulation C Finishing tipe D Liquid pip...

Страница 22: ...electrical parts 4 6kW 8 10 12 14 16kW WARNING Cut off all power supply i e unit power supply and backup heater and domestic hot water tank power supply if applicable before removing doors 1 Parts ins...

Страница 23: ...19 The picture is for reference only please refer to the actual product NOTE PCB A PCB B 12 14 16kW 1 phase PCB A PCB B PCB C 12 14 16kW 3 phase Back PE1 PE2 CN30...

Страница 24: ...B B CN32 Input port L for rectifier bridge CN501 Input port N for rectifier bridge CN502 1 2 3 CN20 CN19 CN32 CN502 CN23 CN6 CN501 4 8 5 6 7 9 10 1 2 3 4 5 Assembly unit Assembly unit Coding Coding 6...

Страница 25: ...play DSP1 Port for chassis electrical heating tape CN16 optional Port for compressor eletric heating tape 1 CN7 Port for 4 way value CN6 Port for SV6 value CN5 Port for compressor eletric heating tape...

Страница 26: ...unit Assembly unit Coding Coding 9 10 11 12 13 8 Compressor connection port W CN19 Compressor connection port U CN17 Power Input port L3 CN15 Power Input port L1 CN16 Power Input port L2 CN7 Port for...

Страница 27: ...und wire CN38 Port for eletric heating tape2 CN7 Port for 4 way value CN18 Reserved CN11 Port for outdoor ambient temp sensor and condenser temp sensor CN9 8 10 11 12 13 Port for eletric heating tape1...

Страница 28: ...er ltering L2 L2 Power ltering L3 L3 3 PCB C filter board PCB C 3 phase 12 14 16kW PE1 PE2 PE3 CN202 CN201 CN200 CN203 CN204 CN205 CN206 CN212 CN211 CN8 CN213 CN214 CN30 2 5 4 3 6 13 12 7 8 9 10 11 14...

Страница 29: ...ly Install leak alarm facility related to mechanical ventilator if you can not regularly ventilate 2 Requirments for charge limits in unventilated areas The maximum refrigerant charge in appliance sha...

Страница 30: ...s filled of leakage refrigerant All refrigerant has leaked out 8 10 12 14 16 kW Fig 11 2 Fig 11 3 12 TURN OVER TO CUSTOMER The owner s manual of indoor unit and owner s manual of outdoor unit must be...

Страница 31: ...ed object The remote controller may be damaged Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Do not use the heat pump for other purposes In order to avoid...

Страница 32: ...2 About power cut If power is cut during operation stop all the operation immediately Power comes again If the auto restart function is set on then the unit will auto restart Mishandling in operation...

Страница 33: ...T4 error 1 The Th sensor connector is loosen Re connect it 2 The Th sensor connector is wet or there is water in remove the water make the connector dry Add waterproof adhesive 3 The Th sensor failure...

Страница 34: ...or Pressure sensor failure Refer to P0 Low pressure protection in cooling Pe 0 6 occurred 3 times in an hour Refer to H6 H6 displayed 10 times in 2 hours 1 The EEprom parameter is error rewrite the EE...

Страница 35: ...on High pressure switch protection 1 The same reason to P1 2 TW_out temp sensor is loosen Reconnect it 3 T1 temp sensor is loosen Reconnect it 4 T5 temp sensor is loosen Reconnect it High discharge te...

Страница 36: ...And if those IGBT are OK which means the inverter board is OK power form rectifier bridge is not correct check the bridge Same method as IGBT disconnect the power check those dioxides are damaged or n...

Страница 37: ...protection MCE malfunction 1 Check the Heat pump system pressure 2 Check the phase resistance of compressor 3 Check the U V W power line connection sequence between the inventer board and the compres...

Страница 38: ...quid side Drain connection Max piping length 30m Max differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin...

Страница 39: ...differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin coil Refrigerant R32 Weight Connections 9 52 220 24...

Страница 40: ...he period that the work is carried out The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere 8 Checks to the refrigeration equipment Wh...

Страница 41: ...sed the system shall be vented down to atmospheric pressure to enable work to take place This operation is absolutely vital if brazing operations on the pipe work are to take place Ensure that the out...

Страница 42: ...or decommissioning it is recommended good practice that all refrigerants are removed safely When tranferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are...

Страница 43: ...pansion Valve Single way electromagnetic valve Filter Discharge temperature sensor Outdoor temperature sensor Outdoor exchanger sensor Stop valve gas Stop valve liquid High Pressure Switch Low Pressur...

Страница 44: ...r reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supply volatge 230VAC NOTE ANNEX B To install the E heating tape at the drainage outlet b...

Страница 45: ...ase 12 14 16kW 3 phase XT3 To the heating tape of drainage outlet A The picture is for reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supp...

Страница 46: ...16125300002360 V4 0...

Страница 47: ......

Страница 48: ......

Отзывы: