5 INSTALLATION SITE

Be sure to adopt adequate measures to prevent the unit from being used as a shelter by small animals.Small 

animals making contact with electrical parts can cause malfunction, smoke or fire. Please instruct the customer to 

keep the area around the unit clean.

WARNING

Frequency of Refrigerant Leakage Checks
- Equipment that contains less than  3 kg  of  fluorinated  greenhouse  gases  or  hermetically  sealed  equipment,

which  is  labelled  accordingly  and  contains less  than  6 kg  of  fluorinated  greenhouse  gases  shall  not  be

subject  to  leak  checks.
- For unit that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO

2

 equivalent or more,but of

less than 50 tonnes of CO

2

 equivalent,at least every 12 months, or where a leakage detection system is installed,

at least every 24 months.
- Only certificated person is allowed to do installation, operation and maintenance.

CAUTION

Select an installation site where the following condition sare satisfied and one that meets with your customer's approval.
- Places that are well-ventilated.
- Places where the unit does not disturb next-door neighbors.
- Safe places which can bear the unit's weight and vibration and where the unit can be installed at an even level.
- Places where there is no possibility of flammable gas or product leak.
- The equipment is not intended for use in a potentially explosive atmosphere.
- Places where servicing space can be well ensured.
- Places where the units' piping and wiring lengths come within the allowable ranges.
- Places where water leaking from the unit cannot cause damage to the location (e.g. in case of a blocked drain pipe).
- Places where rain can be avoided as much as possible.
- Do not install the unit in places often used as a work space. In case of construction work (e.g. grinding etc.) where a lot of

dust is created, the unit must be covered.
- Do not place any object or equipment on top of the unit (top plate)
- Do not climb, sit or stand on top of the unit.
- Be sure that sufficient precautions are taken in case of refrigerant leakage according to relevant local laws and

regulations.- Don’t install the unit near the sea or where there is corrosion gas.
When installing the unit in a place exposed to strong wind, pay special attention to the following.
Strong winds of 5 m/sec or more blowing against the unit's air outlet causes a short circuit (suction of discharge air), and this 

may have the following consequences:
- Deterioration of the operational capacity.
- Frequent frost acceleration in heating operation.
- Disruption of operation due to rise of high pressure.
- Motor burnout.
- When a strong wind blows continuously on the front of the unit, the fan can start rotating very fast until it breaks.

07

Factory charged refrigerant volume in the unit

Refrigerant/kg 

Tonnes CO

2

 equivalent

1-phase 12kW

1.84

1.24

1-phase 14kW

1.84

1.24

1-phase 16kW

1.84

1.24

3-phase 12kW

1.84

1.24

3-phase 14kW

1.84

1.24

3-phase 16kW

1.84

1.24

Model

Содержание Aquantia R-32 PRO

Страница 1: ...please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL Aquantia R 32 PRO Mural Bibloc Outdoor Unit KHP BI 4 DVR2 KHP BI 6 DVR2 KHP BI 8 DVR2 KHP BI 10 DVR2 KHP...

Страница 2: ......

Страница 3: ...Installation requirements Drain hole position Installation space requirements 6 1 6 2 6 3 6 4 6 SAFETY PRECAUTIONS ACCESSORIES BEFORE INSTALLATION IMPORTANT INFORMATION FOR THE REFRIGERANT INSTALLATIO...

Страница 4: ...IONS ON REFRIGERANT LEAKAGE 25 26 34 28 28 28 28 28 28 Protection equipment About power cut Heating capcity Compressor protection feature Cooling and heating operation Features of heating operation De...

Страница 5: ...stallation NOTE Please remove the noise insulation cover of the compressor first Please make sure the transportation support had be removed It will cause heat pump abnormal vibration and noise if runn...

Страница 6: ...ded into the following types They are quite important so be sure to follow them carefully Meanings of DANGER WARNING CAUTION and NOTE symbols Indicates an imminently hazardous situation which if not a...

Страница 7: ...ire Make sure all wiring is secure Use the specified wires and ensure that terminal connections or wires are protected from water and other adverse external forces Incomplete connection or affixing ma...

Страница 8: ...ed Children should not play with the unit Cleaning and user maintenance should not be done by children without supervision Children should be supervised to ensure that they do not play with the applia...

Страница 9: ...ation Fittings Water outlet connection pipe assembly Before installation Be sure to confirm the model name and the serial number of the unit Handling 3 BEFORE INSTALLATION Energy label 1 05 1 Handle t...

Страница 10: ...GERANT This product has the fluorinated gas it is forbidden to release to air Refrigerant type R32 Volume of GWP 675 GWP Global Warming Potential Factory charged refrigerant volume in the unit Refrige...

Страница 11: ...sive atmosphere Places where servicing space can be well ensured Places where the units piping and wiring lengths come within the allowable ranges Places where water leaking from the unit cannot cause...

Страница 12: ...avoild direct sunlight so that it is not influenced by the sun s heat otherwise protection may be possible to the unit Make sure there is enough space to do the installation Set the outlet side at a r...

Страница 13: ...ng the operation In accordance with the foundation drawing in the figure fix the unit securely by means of foundation bolts Prepare four sets each of 10 Expansion bolts nuts and washers which are read...

Страница 14: ...nit with the base electric heater CAUTION Drain hole This drain hole is covered by rubber plug If the small drain hole can not meet the drainage requirements the big one can be used at the same time 5...

Страница 15: ...er row Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 150 600 1 2 H B2 A B1 C H 500mm 500mm 1 2 H B2 A B1 C H Unit A mm B1 mm B2 mm C mm 4 16kW 3000 2000 300 600 11 7 INSTALL THE CONNECTING PIPE 7 1 Refr...

Страница 16: ...D C 7 3 Heat insulation In order to avoid the release of cold or heat from the connecting pipeline to the external environment during the operation of the equipment please take effective insulation m...

Страница 17: ...R32 R32 4 6kW MODEL 15 9 9 52 7 4 Connecting method Indoor Unit Outdoor Unit H Gas side Liquid side Flaring Flaring Flaring Flaring 4 16 kW 30m 20m Figure 7 5 4 16kW outdoor unit Indoor unit Models Ma...

Страница 18: ...valves 2 The airtight testing should never use any oxygen flammable gas or poisonous gas 7 7 Air purge with vacuum pump 1 Using vacuum pump to do the vacuum never using refrigerant to expel the air 2...

Страница 19: ...heating of the capacitor due to high frequency waves Never install a phase advancing capacitor as it could lead to an accident Secure the electrical wiring with cable ties as shown in figure so that...

Страница 20: ...wire diameters should be selected according to the national wiring regulation 2 Select circuit breaker that having a contact separation in all poles not less than 3 mm providing full disconnection whe...

Страница 21: ...NOTE A B C D E F 8 5 To finish the outdoor unit installation insulate and fix the refrigerant piping and interconnection cable as follows A Gas pipe B Gas pipe insulation C Finishing tipe D Liquid pip...

Страница 22: ...electrical parts 4 6kW 8 10 12 14 16kW WARNING Cut off all power supply i e unit power supply and backup heater and domestic hot water tank power supply if applicable before removing doors 1 Parts ins...

Страница 23: ...19 The picture is for reference only please refer to the actual product NOTE PCB A PCB B 12 14 16kW 1 phase PCB A PCB B PCB C 12 14 16kW 3 phase Back PE1 PE2 CN30...

Страница 24: ...B B CN32 Input port L for rectifier bridge CN501 Input port N for rectifier bridge CN502 1 2 3 CN20 CN19 CN32 CN502 CN23 CN6 CN501 4 8 5 6 7 9 10 1 2 3 4 5 Assembly unit Assembly unit Coding Coding 6...

Страница 25: ...play DSP1 Port for chassis electrical heating tape CN16 optional Port for compressor eletric heating tape 1 CN7 Port for 4 way value CN6 Port for SV6 value CN5 Port for compressor eletric heating tape...

Страница 26: ...unit Assembly unit Coding Coding 9 10 11 12 13 8 Compressor connection port W CN19 Compressor connection port U CN17 Power Input port L3 CN15 Power Input port L1 CN16 Power Input port L2 CN7 Port for...

Страница 27: ...und wire CN38 Port for eletric heating tape2 CN7 Port for 4 way value CN18 Reserved CN11 Port for outdoor ambient temp sensor and condenser temp sensor CN9 8 10 11 12 13 Port for eletric heating tape1...

Страница 28: ...er ltering L2 L2 Power ltering L3 L3 3 PCB C filter board PCB C 3 phase 12 14 16kW PE1 PE2 PE3 CN202 CN201 CN200 CN203 CN204 CN205 CN206 CN212 CN211 CN8 CN213 CN214 CN30 2 5 4 3 6 13 12 7 8 9 10 11 14...

Страница 29: ...ly Install leak alarm facility related to mechanical ventilator if you can not regularly ventilate 2 Requirments for charge limits in unventilated areas The maximum refrigerant charge in appliance sha...

Страница 30: ...s filled of leakage refrigerant All refrigerant has leaked out 8 10 12 14 16 kW Fig 11 2 Fig 11 3 12 TURN OVER TO CUSTOMER The owner s manual of indoor unit and owner s manual of outdoor unit must be...

Страница 31: ...ed object The remote controller may be damaged Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Do not use the heat pump for other purposes In order to avoid...

Страница 32: ...2 About power cut If power is cut during operation stop all the operation immediately Power comes again If the auto restart function is set on then the unit will auto restart Mishandling in operation...

Страница 33: ...T4 error 1 The Th sensor connector is loosen Re connect it 2 The Th sensor connector is wet or there is water in remove the water make the connector dry Add waterproof adhesive 3 The Th sensor failure...

Страница 34: ...or Pressure sensor failure Refer to P0 Low pressure protection in cooling Pe 0 6 occurred 3 times in an hour Refer to H6 H6 displayed 10 times in 2 hours 1 The EEprom parameter is error rewrite the EE...

Страница 35: ...on High pressure switch protection 1 The same reason to P1 2 TW_out temp sensor is loosen Reconnect it 3 T1 temp sensor is loosen Reconnect it 4 T5 temp sensor is loosen Reconnect it High discharge te...

Страница 36: ...And if those IGBT are OK which means the inverter board is OK power form rectifier bridge is not correct check the bridge Same method as IGBT disconnect the power check those dioxides are damaged or n...

Страница 37: ...protection MCE malfunction 1 Check the Heat pump system pressure 2 Check the phase resistance of compressor 3 Check the U V W power line connection sequence between the inventer board and the compres...

Страница 38: ...quid side Drain connection Max piping length 30m Max differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin...

Страница 39: ...differance in height 20m Heating mode Cooling mode Domestic hot water mode 15 9 DN32 Operation ambient temperature range 25 35 C 5 43 C 25 43 C Fin coil Refrigerant R32 Weight Connections 9 52 220 24...

Страница 40: ...he period that the work is carried out The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere 8 Checks to the refrigeration equipment Wh...

Страница 41: ...sed the system shall be vented down to atmospheric pressure to enable work to take place This operation is absolutely vital if brazing operations on the pipe work are to take place Ensure that the out...

Страница 42: ...or decommissioning it is recommended good practice that all refrigerants are removed safely When tranferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are...

Страница 43: ...pansion Valve Single way electromagnetic valve Filter Discharge temperature sensor Outdoor temperature sensor Outdoor exchanger sensor Stop valve gas Stop valve liquid High Pressure Switch Low Pressur...

Страница 44: ...r reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supply volatge 230VAC NOTE ANNEX B To install the E heating tape at the drainage outlet b...

Страница 45: ...ase 12 14 16kW 3 phase XT3 To the heating tape of drainage outlet A The picture is for reference only please refer to the actual product The power of the E heating tape shall not exceed 40W 200mA supp...

Страница 46: ...16125300002360 V4 0...

Страница 47: ......

Страница 48: ......

Отзывы: