ka yd en
. c o m
5
Introd
uction
CLASSIC 800 Product Manual
Display Panel Indicators:
Relay 1
On steady when Relay 1 is energized
Relay 2
On steady when Relay 2 is energized
Fault
Indicates a self-test error or fault condition
Set Point 1
On steady when v
iewing Set Point 1
Set Point 2
On steady when v
iewing Set Point 2
Run Mode
Flashing when switch/transmitter is operating
Bypass
Flashing when the Start-up Bypass Timer is activ
e
Thermal Signal
Displays Thermal Signal
The Thermal Signal increases as:
Flow
The flow rate increases
Level
The sensor is submerged
Interface
The sensor is submerged by the second liquid of
greater thermal conductiv
ity
Display Panel & Intelligent User Interface
The Kayden CLASSIC 800 Electronics Module is designed to be easy to install and adjust while displaying
sev
eral control functions. All Kayden CLASSIC 800 Electronics Modules feature:
•
Univ
ersal Power Input
•
4-20 mA Analog Output
•
Continuous Self-test diagnostics with Fault Indicator
•
Start-up Bypass Timer
•
Easy setup; no jumpers or trim pots
•
True Temperature Compensation
•
Incrementally adjustable heater power, range and
relay set points.
•
All CLASSIC 800 series switches/transmitters use the same Electronics Module making it a univ
ersal
spare part. The Electronics Module is easily installed in the field without returning the entire
switch/transmitter to the factory.
Figure 1
- CLASSIC 800
Display Panel
•
Pump Protection – Dry Alarm
•
Leak Detection
•
Flow Monitoring & Verification
•
Tank Ov
erflow Protection
•
Flare Gas Monitoring
•
Monitoring Purge Air Flow
•
Drain Line Flow
•
Interface Control in Separation Vessels
•
High Pressure Flows
•
Lube Oil Systems
•
Vent Monitoring
•
Natural G as to Boilers
•
Emergency Eye Wash Stations
•
Tanker Loading & Unloading
•
Relief Valv
e & Rupture Disk Flow Monitoring
•
Remote Indication of Flow v
ia Analog Output
& Digital Communications
•
Liquids, Air & Gases
•
Slurries
•
Interface Detection
•
Corrosiv
e Liquids
•
Hazardous & General-Purpose Areas
•
Interface Control & Lev
el Detection in Settling Vessels
•
Chemical Injection/Additiv
e Flow Monitoring
CLASSIC 800 Electronics
Typical Applications
25472-1 01 -V1 A-JF00-W0010 Rev 02
Содержание CLASSIC 800 Series
Страница 2: ...25472 101 V1A JF00 W0010 Rev 02...
Страница 3: ...25472 101 V1A JF00 W0010 Rev 02...
Страница 73: ...kayden com 65 CLASSIC 800 CLASSIC 800 Product Manual Notes 25472 101 V1A JF00 W0010 Rev 02...
Страница 74: ...kayden com 66 CLASSIC 800 CLASSIC 800 Product Manual Notes 25472 101 V1A JF00 W0010 Rev 02...