Page no. 21 | Appendix No. 1
8
Mechanical Properties
8.1
Camera Mechanical Drawings
Figure 10 – Iron SDI mechanical dimensions
8.2
GPIO Pinout
The GPIO connector in use is an HR10A-10P-12P(74) female (Hirose Electric). The female 12-pin HIROSE connector
provides camera control via an RS232 serial interface and outputs Lens Control signals for Zoom, Focus, and Iris
for a standard C-Mount and CS-Mount motorized lenses. The following figure describes the pin out of the Iron
CoaXPress camera Hirose 12 pin female connector.
Figure 11 – Iron SDI GPIO connector pinout
8.2.1
Iron SDI Camera GPIO pinout description:
Pin Number
Pin Description
Direction
1
DC Power return
GND
2
DC Power
Input
3
Reserved
4
Reserved
5
OUT2 RTN (opto)
Output
6
OUT1 RTN
Output
7
OUT1 (TTL)
Output
8
IN1 (opto isolated)
Input
9
IN2 (LVTTL)
Input
10
IN1 RTN
Input
11
IN2 RTN
Input
12
OUT2 (opto isolated)
Output
Table 5 – Iron SDI GPIO connector pinout