Instructions for use EXPERTtorque E680 - 1.006.4700EXPERTtorque Mini E677 - 1.006.0100

2 Safety | 2.1 Infection hazard

6 / 26

2 Safety

The instructions for use are a component of the product and must be read care-
fully prior to use and be accessible at all times.
The device may only be used in accordance with the intended use, any other
type of use is not permitted.

2.1 Infection hazard

Patients, users or third parties can be infected by contaminated medical de-
vices.

Take suitable personal protective measures.

Follow the instructions for use of the components.

Before initial startup and after each use, process the product and acces-
sories appropriately.

Carry out the processing as described in the instructions for use. The proce-
dure has been validated by the manufacturer.

If you deviate from this procedure, it is essential to make sure that the pro-
cessing is effective.

Prior to disposal, the product and accessories must be appropriately pro-
cessed and sterilized.

In the case of injury to soft tissue, do not continue treatment in the oral
cavity with instruments driven by compressed air.

2.2 Technical condition

A damaged device or components can injure patients, users and third parties.

Use the device and components only if there is no damage on the outside.

Check to make sure that the device is working properly and is in satisfac-
tory condition before each use.

Have parts with sites of breakage or surface changes checked by the Ser-
vice.

If the following defects occur, stop working and have the service personnel
carry out repair work:

▪ Malfunctions

▪ Damage

▪ Irregular running noise

▪ Excessive vibration

▪ Overheating

▪ Dental bur or diamonds is not firmly locked in the handpiece

To ensure optimum function and to prevent property damage, please comply
with the following instructions:

Service the medical device with care products and systems regularly as de-
scribed in the instructions for use.

The device should be cleaned, serviced and stored in a dry location, accord-
ing to instructions, if it is not to be used for an extended period of time.

Содержание EXPERTtorque Mini E677

Страница 1: ...Instructions for use EXPERTtorque E680 1 006 4700 EXPERTtorque Mini E677 1 006 0100...

Страница 2: ...stributed by KaVo Dental Technologies LLC 11727 Fruehauf Drive Charlotte NC 28273 USA Phone 847 550 6800 Fax 847 550 6825 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo c...

Страница 3: ...amond 13 6 Troubleshooting 15 6 1 Cleaning the spray nozzle 15 6 2 Changing the water filter 15 7 Processing steps in accordance with ISO 17664 16 7 1 Preparations at the site of use 16 7 2 Manual pro...

Страница 4: ...vice For scheduling or if you have any questions please contact KaVo Repair Service KaVo Dental Technologies LLC 11727 Fruehauf Drive Charlotte NC 28273 USA Toll free Direct Customer Service 1 888 ASK...

Страница 5: ...conditions Air pressure Transportation and storage conditions Humidity range Protect from moisture Keep dry Fragile handle with care HIBC Code Hazard levels The warning and safety notes in this docum...

Страница 6: ...e appropriately pro cessed and sterilized In the case of injury to soft tissue do not continue treatment in the oral cavity with instruments driven by compressed air 2 2 Technical condition A damaged...

Страница 7: ...the handpiece head or handpiece lid to soft tissue Do not use the medical device as a light probe Use an appropriate light probe for illumination of the oral cavity or site of preparation After treat...

Страница 8: ...e devices can be sterilized in a steam sterilizer autoclave The EXPERTtorque LUX E680 and the EXPERTtorque Mini LUX E677 are connected to the dental treatment unit by an inside hose and the coupling a...

Страница 9: ...otect himself or herself the patient and third parties from danger and avoid contamination from the product 3 2 Technical Specifications NSK PTL CL LED3 Drive pressure bar 2 0 3 0 Drive pressure recom...

Страница 10: ...before disposal See also 2 7 Processing steps in accordance with ISO 17664 Page 16 NOTICE Damage from contaminated and moist cooling air Contaminated and moist cooling air can cause malfunctions Make...

Страница 11: ...re wear Supply dry clean and uncontaminated compressed air in accordance with ISO 7494 2 only Insert the test manometer Mat no 0 411 8731 between the coupling and the medical device and check the foll...

Страница 12: ...e cou pling or reduce its service life Make sure that the high speed air handpiece is accurately coupled and firmly seated on the coupling Accurately attach the medical device to the coupling and push...

Страница 13: ...erty damage to tool shaft and chuck system reduction of the service life of tool and chuck system Do not operate the tool at a higher speed than recommended by the manu facturer NOTICE Use of burs wit...

Страница 14: ...ERTtorque E680 1 006 4700EXPERTtorque Mini E677 1 006 0100 5 Operation 5 4 Removing the bur or diamond 14 26 After the bur has stopped rotating firmly press the push button with your thumb and simulta...

Страница 15: ...it if needed 6 2 Changing the water filter WARNING Hazard from non sterile products Infection hazard for dentist and patient Reprocess and sterilize the medical device properly before the next use CA...

Страница 16: ...e the tool Process the medical device as soon as possible after treatment To minimize the risk of infection during processing always wear protective gloves Remove the tool from the medical device Remo...

Страница 17: ...the disinfectant manufacturer and proven by an expert opinion CaviCide made by Metrex Consumables required Cloths for wiping the medical device Spray the disinfectant on a cloth then wipe down the me...

Страница 18: ...compliance with ISO 15883 1 which are operated using alkaline cleaning agents having a maximum pH value of 10 For program settings as well as cleansers and disinfectants to be used please refer to the...

Страница 19: ...m the medical device Position the tip of the spray nipple in the opening and apply the spray Press the spray key once for 1 2 seconds 7 4 2 Servicing with KaVo QUATTROcare PLUS Servicing and cleaning...

Страница 20: ...hes back to normal service mode See also 2 Servicing with KaVo QUATTROcare PLUS 7 5 Packaging Note The sterilization bag must be large enough for the handpiece to fit without stretching the bag The qu...

Страница 21: ...75 F Drying time 30 min Sterilizer using the gravity method at least 60 minutes at 121 C 250 F Drying time 15 min Remove contra angle handpieces and turbines immediately after the com pletion of the s...

Страница 22: ...411 3053 Wrench for lid of EXPERTtorque Mini new 1 008 6133 Wrench for lid of EXPERTtorque Mini old 1 006 3384 Replacement filter 1 002 0271 Wrench 1 002 0321 Instrument stand 2151 0 411 9501 Insert f...

Страница 23: ...for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calci...

Страница 24: ......

Страница 25: ......

Страница 26: ...1 009 2488 bd 20171103 03 en US...

Отзывы: