12
Electric Dispenser Hoist EWL 2, 3, 4
Hook the load hook
6
into the bracket
h
again and raise the full plaster container to
the stop by operating the button
g
.
Load hook
6
with suspended pla-
ster container
j
is stopped at the
upper limit stop by an auto-matic limit
switch.
Move the carriage
1
in the direction of the
arrow to the rear limit stop.
Operate the button
d
to lower the plaster
container in the direction of the console
k
.
During the lowering process, push
the container
j
against the con-sole
k
. The container
j
must engage fully in
the supports of the console
k
.
Lower the load hook
6
to the cover
f
stop. Move the carriage
1
slightly for-
wards and raise the load hook
6
to the
stop by operating the button
g
.
Slide the carriage
1
up to the limit stop on
the guide rail
2
. Raise the load arm
3
and
move it to the left into the parking position.