Instructions for use SMARTmatic PROPHY S19 - 1.011.6740 SMARTmatic PROPHY S19 K - 1.011.6741

9 Terms and conditions of warranty

9 Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:

KaVo provides the end customer with a warranty of proper function and guarantees
zero defects in respect of material and processing for a period of 12 months from the
date of the invoice, subject to the following conditions:
In case of justified complaints, KaVo will honour its warranty with a free replacement
or repair. Other claims of any nature whatsoever, in particular with respect to com-
pensation, are excluded. In the event of default, gross negligence or intent, this shall
only apply in the absence of mandatory legal regulations to the contrary.
KaVo shall not be liable for defects and their consequences that have arisen or may
arise from natural wear, improper handling, cleaning or maintenance, non-compliance
with operating, maintenance or connection instructions, calcination or corrosion, con-
taminated air or water supplies or chemical or electrical factors deemed abnormal or
impermissible in accordance with KaVo's instructions for use or other manufacturer's
instructions. The warranty granted does not usually extend to lamps, optical fibres
made of glass and glass fibres, glassware, rubber parts, and the colourfastness of
plastic parts.
All liability is excluded if defects or their consequences originate from manipulations or
changes to the product made by the customer or a third party that is not authorised by
KaVo.
Warranty claims will only be accepted if the product is submitted along with proof of
purchase in the form of a copy of the invoice or note of delivery. The dealer, purchase
date, type, and serial number must be clearly evident from this document.

25 / 28

Содержание 1.011.6740

Страница 1: ...Instructions for use SMARTmatic PROPHY S19 1 011 6740 SMARTmatic PROPHY S19 K 1 011 6741...

Страница 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Страница 3: ...ngs 16 7 Reprocessing steps in accordance with ISO 17664 17 7 1 Preparations at the site of use 17 7 2 Cleaning 17 7 2 1 Manual external cleaning 17 7 2 2 Automated external cleaning 17 7 2 3 Manual i...

Страница 4: ...avo com Target group This document is intended for dentists and their assistants The startup section is also intended for service technicians General marks and symbols Refer to the chapter on Safety W...

Страница 5: ...PROPHY S19 1 011 6740 SMARTmatic PROPHY S19 K 1 011 6741 1 User instructions CAUTION In cases which if not prevented could lead to minor or moderate injury NOTICE In cases which if not prevented coul...

Страница 6: ...In the case of injury to soft tissue do not continue treatment in the oral cavity with instruments driven by compressed air Use gloves or finger guard whenever you test insert and remove the tool 2 2...

Страница 7: ...acility for changing the speed and the direction of rotation must be present The medical device may only be combined with a treatment centre released by KaVo Comply with the Instructions for Use of th...

Страница 8: ...19 K 1 011 6741 2 Safety 2 5 Service and repair 8 28 KaVo recommends specifying in house service intervals where the medical device is brought to a professional shop for cleaning servicing and a funct...

Страница 9: ...ool to support the periodontal treatment by polish ing with a rotating tool A medical device according to relevant national statutory regulations Proper use According to these provisions this medical...

Страница 10: ...mission 8 1 Cooling air flow 5 5 to 9 5 Nl min Prophylaxis heads with a Doriot connector can be inserted Shaft and or drive shaft in accordance with DIN EN ISO 14457 for metallic and ceramic materials...

Страница 11: ...Transportation and storage conditions NOTICE Startup after refrigerated storage Malfunction Prior to startup very cold products must be heated up to a temperature of 20 C to 25 C 68 F to 77 F Temperat...

Страница 12: ...Dispose of the product in appropriate manner Infection hazard Before disposal reprocess and sterilise the product and accessories appropri ately NOTICE Damage from soiled and moist cooling air Contami...

Страница 13: ...to ensure that it is se curely locked onto the motor coupling NOTICE Removing and attaching the handpiece while the drive motor is rotating Damage to the driver Never attach or remove the handpiece w...

Страница 14: ...is heads Injury to the patient or damage to the medical device Comply with the instructions for use and the intended use of the tools Only use prophylaxis heads that do not deviate from the specified...

Страница 15: ...the prophylaxis head 5 4 Removing the prophylaxis head Remove the prophylaxis head axially from the handpiece CAUTION Hazard due to incorrectly stored instrument Injury and infection from clamped prop...

Страница 16: ...is irregularly heated The medical device is too hot while working Service the medical device When the speed drops or is uneven Service the medical device An O ring is missing on the motor coupling Re...

Страница 17: ...lly or in a washer disinfector only 7 2 1 Manual external cleaning Accessories required Tap water 30 o C 5 o C 86 o F 10 o F Brush e g medium hard toothbrush Brush off under flowing tap water 7 2 2 Au...

Страница 18: ...line cleaning agents The validations were conducted with the VARIO TD program the cleaning agent neodisher MediClean and the neutralisation agent neodisher Z For program settings as well as cleansers...

Страница 19: ...external and internal disinfection KaVo recommends washer disinfectors in compliance with EN ISO 15883 1 that are operated with alkaline cleaning agents The validations were conducted with the VARIO T...

Страница 20: ...rvicing with KaVo Spray KaVo recommends servicing the product as part of the reprocessing after each use i e after each cleaning disinfection and before each sterilisation Remove the tool Cover the pr...

Страница 21: ...xpansion pressure for the interior cleaning of inor ganic residues and optimum care no validated cleaning of the interior in accordance with German RKI requirements KaVo recommends servicing the produ...

Страница 22: ...rvice button for at least three seconds until the spray canister control LED flashes three times consecutively The device is in chuck service mode Remove the service coupling of the chuck from the sid...

Страница 23: ...to moisture Damage to product Immediately remove the product from the steam steriliser after the sterilisation cycle The KaVo medical device has a maximum temperature resistance up to 138 280 4 F Sele...

Страница 24: ...ent stand 2151 0 411 9501 Cleanpac 10 units 0 411 9691 Cellulose pad 100 units 0 411 9862 Spray head INTRA KaVo Spray 0 411 9911 INTRA service coupling 1 009 6143 Material summary Mat No KaVo Spray 21...

Страница 25: ...for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calcin...

Страница 26: ......

Страница 27: ......

Страница 28: ...1 010 0216 s 20170120 2 en...

Отзывы: