CONTROL CONNECTOR PINOUT
(FEMALE DB
1
5)
PIN
USAGE NOTES
2 & 3
Normally Open Fault Relay Dry
Contacts (1A, 28 VDC max.)
Per Module fault indication. Not
the same as the signal on the
expansion cable connector.
10 Transmit
11 Receive
15 Ground
RS-232 compatible signals for
connection to a PC using
CAB000000057 cable.
6 SIG
7 TX
Disable
8 Ground
Module Interconnection for
special application. Consult
factory.
1,4,5,9,12,13,14
Reserved, Do Not Use.
Running the program
The software allows a terminal emulation program to access the digital information
stored in the module. This same program will be used to modify the parameters in
every type of module in the system. Since not all modules will have the same types
or values for parameters, it is very important that the user know the type of module
to be changed, the types of parameters that may be changed, the range of values,
the current values of the parameters, and finally the target or desired values for
those parameters. To facilitate this, these values are included in this manual in the
section for each type of module, and KAVAL TELECOM INC. recommends that any
modified values be recorded in that section of the manual.