flashing mean in running mode. 

 

7.-

  In  the  process  of  discharge,  battery  voltage  is  decrease,  when  battery  voltage  less  than 

configuration  voltage,  tester  will  automatic  stop  discharge.  If  use  quickly  test  model,  when 

time counter to zero will stop battery discharge, display flashing and BUZZER alarm user to 

check the result. Tester will show battery capacity, user can press any key stop alarm. And 

press

key to see each parameter test result. 

8.-

can reset AH to zero; in discharging time 

display screen, press and hold key can reset time to zero. 

Notes:

 Both values will automatic reset to zero after power off. 

9.- 

Remove battery clip, product automatic power off, then can start another battery test. 

10.-

 If user want accurate test result or test low voltage battery like Li battery, we suggest to use 

3-Wire connection, in this mode need connect AUX power, other configuration is the same as 

the two wire mode. 

 

Product wire jump to 3-Wire mode, connect the DC5V power adapter,(or use your local adapter, 

DC output 5~30V) system start discharging. 

Notes:

 In 3-Wire mode, first connected the aluminum resistor and the power adapter, then 

configure  the  parameter  values,  finally  connect  the  measured  battery  to  start  test. 

need to manually cleared AH and discharging time when replace the battery. 

 In AH value display screen, press and hold key

SUPPLIMENTARY EXPLANATION 

 

1. Quickly  test  is  the  unique  function  of  FDY  battery  tester,  do  not  need  battery  full charged, nor

discharge  to  stop  voltage.  If  battery SOC  is  25%  -75%,  the  test  result  has higher accuracy.

Notes:

  Set  a  suitable  discharge  amp  value  and  discharge  time  is  necessary  to  increase  the accuracy of test

specifically, because different battery have unique discharge curve, so please  try to find the best configuration 

value suit for your battery, user can following three principles: 

1.1.- Different battery has different stop discharge voltage. 

1.2.- Maximum discharging amp always 1C. For exampl e battery capacity is 3AH, maximum amp 

set 3A, and battery discharge time can set 1minute. Set smaller discharge amp and longer 

test time will make the test result has higher accuracy, Blue Jay listed below an experience 

table, for reference: 

Battery types 

Voltage is 12V Capacity is 12AH 

Voltage is 3.7V Capacity is 2.5AH 

Stop Voltage 

10.5V 

10.5V 

10.5V 

3.0V 

3.0V 

3.0V 

Current 

10A 

5A 

3A 

2A 

1A 

0.6A 

Test Time 

1minute 

2minutes  3minutes  1minute 

2minutes  3minutes 

Содержание FDY10

Страница 1: ...FDY10 Battery Tester User Manual Version 2 0 ...

Страница 2: ...wire measurement eliminating the voltage drop due to the internal resistance of the cable the connection between the battery and the tester measurement error more accurate measurements Display part use 6 LED indicator and 4 Digital display 6LED indicator show display details 4 battery parameter in resolution 0 01V 0 01A Automatic switching display all the battery main parameter volt amp watt AH ru...

Страница 3: ...ction mode the setting is invalid actual discharging current is determined by the resistance of thebattery voltage and external power please refer the detail in OPERATION section Stop discharge voltage 0 00V to 20 00V voltage setting step in 10V is 0 01V setting step over voltage over 10V 10V is 0 1V Measuring voltage accuracy 4 Digital display 10mV to 20 accurate 10mV error 0 5 Measuring current ...

Страница 4: ...erminal 3 After power on the tester will automatic work default display voltage value stop discharge voltage is 10 5V Default discharge current is 10A 4 If want to change current press key LED lamp A is flashing Then press and key to set quick discharge amp value 1A 2AO10A Press OK key enter quit this is quickly setting mode if want to set detail amp value in step 100mA please access the setup mod...

Страница 5: ...tion mode 5 5 Function 5 quickly test setup Notes This function default is off display show F 00 means not use quickly test function Setup value is F 01 to F 10 mean discharge time is 1minute to 10minute press or key set quickly test time after setup save and exit In quickly test quick test time is the configure time 5 6 Function 6 constant resistance mode Notes This function default is off tester...

Страница 6: ...and the power adapter then configure the parameter values finally connect themeasured battery to start test need to manually cleared AH and discharging time when replace the battery In AH value display screen press and hold key SUPPLIMENTARY EXPLANATION 1 Quickly test is the unique function of FDY battery tester do not need battery full charged nor discharge to stop voltage If battery SOC is 25 75...

Страница 7: ...ttery must change resistance to1 ohmor tester will not work 2 2 If still using the 1 ohm resistor user can parallel a 100uH toroid inductor Only to make sure the toroid nductor can reach 10A maximum current Blue Jay also provide this inductance for user testing 3 FDY tester provide constant resistance test mod e In this mode do not use PWM automatic constant current The battery discharge directly ...

Отзывы: