Katranji FDY10 Скачать руководство пользователя страница 4

-

-

 Star/Stop:

 Press "OK" key for start, press again stop. Time and capacity is accumulate, press  and hold 

reset the memory, or auto-reset when power off.

Discharge warning’s:

 the display flick and buzzer warning when discharge stop, press any key  to stop warning. 

External power resistance cooling model:

 when discharge process the resistance is very hot! 

Please avoid touch and place in safety place. 

Dimensions:

 Product: 116*90*40mm, High-power resistance: 165*60*30mm 

Weight:

 190g, High-power resistance: 450g 

key for

OPERATION: 

 

This  product  can  use  external  power,  in  3-Wire  mode l,  if  the  battery  voltage  above  5V,  do  not need external 

power, use 2-Wire. 

 

Following operation guide use 2-Wire model: 

 

1.-

 Set Product wire jump to 2-Wire mode. 

 2.-

 First wiring 1Ω/200W resistance, then wire battery to tester, positive and negative polarities wiring correct. 

Notes:

 please check reliable connection of the wiring, or  will damage the connection terminal!! 

 

3.-

  After  power  on  the  tester  will  automatic  work, default  display  voltage  value,  stop  discharge voltage is 10.5V.

Default discharge current is 10A.

 

4.-

 If want to change current, press 

  key, LED lamp "A" is flashing 

Then press

and

key, to set quick discharge amp value: 1A, 2AO10A. 

Press "OK" key enter quit. this is quickly setting 

mode, if want to set detail amp value in step 

100mA, please access the setup mode. 

Notes:

 If want to change stop discharge voltage, also need access setup mode. 

 

5.-

  Access  setup  mode:  press  and  hold  "

OK

"  key,  voltage  LED  lamp  flashing,  means  now  In setup mode. Press "

OK

" key to select different setup function: 

5.1.- 

Function 1 (setup battery stop discharge voltage): 

Press 

  key  and 

  key  increase  and  decrease  voltage  value,  press  and

  hold key  can 

change value quickly. When voltage precision is 10mV less than 10V setting, over 10V, for 

quickly setup voltage step value is 100mV. 

Digital display 

Voltage 

Current 

ES-n 

AU-n 

F-00 

Cr-n 

LED 

"V" flashing 

"A" flashing 

Function 

Introduction 

Stop discharge 

voltage 

Discharge 

Current 

Save quit 

Automatic 

voltage 

recognition 

Quickly test 

time(min) 

Constant 

resistance 

Содержание FDY10

Страница 1: ...FDY10 Battery Tester User Manual Version 2 0 ...

Страница 2: ...wire measurement eliminating the voltage drop due to the internal resistance of the cable the connection between the battery and the tester measurement error more accurate measurements Display part use 6 LED indicator and 4 Digital display 6LED indicator show display details 4 battery parameter in resolution 0 01V 0 01A Automatic switching display all the battery main parameter volt amp watt AH ru...

Страница 3: ...ction mode the setting is invalid actual discharging current is determined by the resistance of thebattery voltage and external power please refer the detail in OPERATION section Stop discharge voltage 0 00V to 20 00V voltage setting step in 10V is 0 01V setting step over voltage over 10V 10V is 0 1V Measuring voltage accuracy 4 Digital display 10mV to 20 accurate 10mV error 0 5 Measuring current ...

Страница 4: ...erminal 3 After power on the tester will automatic work default display voltage value stop discharge voltage is 10 5V Default discharge current is 10A 4 If want to change current press key LED lamp A is flashing Then press and key to set quick discharge amp value 1A 2AO10A Press OK key enter quit this is quickly setting mode if want to set detail amp value in step 100mA please access the setup mod...

Страница 5: ...tion mode 5 5 Function 5 quickly test setup Notes This function default is off display show F 00 means not use quickly test function Setup value is F 01 to F 10 mean discharge time is 1minute to 10minute press or key set quickly test time after setup save and exit In quickly test quick test time is the configure time 5 6 Function 6 constant resistance mode Notes This function default is off tester...

Страница 6: ...and the power adapter then configure the parameter values finally connect themeasured battery to start test need to manually cleared AH and discharging time when replace the battery In AH value display screen press and hold key SUPPLIMENTARY EXPLANATION 1 Quickly test is the unique function of FDY battery tester do not need battery full charged nor discharge to stop voltage If battery SOC is 25 75...

Страница 7: ...ttery must change resistance to1 ohmor tester will not work 2 2 If still using the 1 ohm resistor user can parallel a 100uH toroid inductor Only to make sure the toroid nductor can reach 10A maximum current Blue Jay also provide this inductance for user testing 3 FDY tester provide constant resistance test mod e In this mode do not use PWM automatic constant current The battery discharge directly ...

Отзывы: