Configuration Menu
25 von 76
No.
Name
Function
①
TIMER OFF
determines whether or not the signal meter automatically
switches off after a certain period of inactivity
OFF
/
5 min
/
10 min
/
15 min
/
30 min
②
UNIT
measurement unit of the HF level that is displayed in the meas-
urement interface
dBm
/
dBµV
/
dBmV
③
LANGUAGE
language of the user interface, 9 language options:
English
/
Italian
/
Spanish
/
German
/
French
/
Portuguese
/
Polish
/
Czech
/
Slovenian
④
KEYS BEEP
volume of key actuation beep; default setting
MEDIUM
OFF
/
MEDIUM
/
LOW
/
HIGH
⑤
DISP. LIGHT
(display lighting)
max. screen brightness; default setting
FULL ON
Other settings automatically reduce the backlighting after
15/30/60 seconds of inactivity to reduce battery drain.
FULL ON
/
15 SEC
/
30 SEC
/
60 SEC
⑥
BATTERY TEST
result of the last battery test
ON
/
255BEEY
(example)
The number (here –
255
) indicates the battery life in minutes.
The letters
BEE
represent a checksum that has no meaning for
the evaluation of the results of the battery test.
The last letter is either
Y
or
N
.
Y
stands for "Yes" and means that
the battery is in working condition.
N
stands for "No" and means
that the battery is defective or that the battery test was inter-
rupted.