background image

20

INSTALLATION OF THE UFS 940SW

The four screw sockets provided (see diagram on the next page) allow you to install the receiver not 
only resting on a shelf but also to 

fi

 x it there or in other positions.

INSTALLATION AND CONNECTION

Note: 

When choosing the installation location, bear in mind that the rear of the unit should always 
be accessible. The UFS 940sw is equipped with a power saving circuit and a separate 
infrared transmitter, which means that the unit does not need to be placed where it is visible. 
You can therefore fi t the UFS 940sw out of sight in any location, e.g. on cupboard walls, 
side walls or the base of storage compartments.

In addition, the following points should be taken into account:

• 

The wall thickness at the installation location must be at least 15 mm, as otherwise the screws will 
break through on the other side or damage the surface

• 

Ensure that the cupboard or storage compartment in which the unit is housed is adequately ventilated, 
to prevent a build up of heat. Carpet-covered walls are unsuitable for installation

• 

Take care when tightening the screws not to damage any cables etc. behind or in the wall

• 

The receiver is designed for installation in exclusively dry, interior locations. The installation location 
must be protected against moisture

• 

The cable lengths must be taken into account when choosing the installation location

• 

The connecting cables must be provided with strain reliefs

Ventilation:
The heat generated within the receiver 
can be dissipated from the following 
sides of the casing: Bottom, left, right 
and top. When selecting the installation 
location, make sure that these sides are 
not obstructed or covered. If the unit is 
operated continuously with insuf

fi

 cient 

ventilation, this can negatively affect the 
length of its working life!

Maintain a clearance of at least 20 cm 

above or below the unit, 2 cm to either 

side and 5 cm behind it, to allow 

unobstructed dissipation of the heat 

generated.

Minimum 

clearance

20 cm

2 cm

2 cm

5 cm

5 cm

SELECTION OF A SUITABLE INSTALLATION LOCATION

The unit monitors its temperature in operation. Premature failure of the unit 
due to continuous operation at temperatures higher than the recommended 
operating temperature as a result of insuffi cient ventilation does not constitute 
grounds for a claim under warranty/guarantee.

Содержание MobiSet 2

Страница 1: ...MobiSet 2 digital CAP 610 Translation of the original operating manual Englisch...

Страница 2: ...e en sat index htm I Lei puo avvere la versione italiana delle istruzioni di montaggio dalla nostra rapresentanza http www kathrein de include kontakte_groups_eng cfm kontinent 1 gruppe SAT piu vicina...

Страница 3: ...gland with sealing gasket Sikaflex 291 adhesive sealant 100 ml tube UFS 940sw HDTV DVB S receiver with connecting cables infrared sensor and infrared remote control MobiSet 2 digital CAP 610 installa...

Страница 4: ...5 CONNECTING TO THE UFS 940SW 25 FUNCTIONAL INSTRUCTIONS FOR CONNECTION TO THE ON BOARD POWER SUPPLY 26 CONNECTION EXAMPLE FOR 12 V BATTERY CONNECTION 27 RECEPTION RANGE FOOTPRINT 28 DISMANTLING FOR S...

Страница 5: ...N 54 LNB TILT SKEW 54 STOP ON SIGNAL 54 MOVE TO THE AZIMUTH ROTATE THE ANTENNA 54 MOVE CAP TO PARK POSITION 55 CAP SETTINGS 55 ELEVATION BORDER AND ELEVATION OFFSET 55 SEARCH SPEED 55 ALIGNMENT SATELL...

Страница 6: ...he components and mounting accessories in the set which could endanger both the mechanical and functional reliability Improper or forcible opening of the components Use of cleaners containing solvents...

Страница 7: ...rson carrying out the repairs Caution Risk of death or injury due to falling or the roof collapsing Nobody should be inside the caravan motor home underneath the antenna during dismantling installatio...

Страница 8: ...that the cable polarity is not reversed If the cable polarity is reversed there is a risk of thermal overload and damage to components when the equipment is powered up Power supply fusing Operate the...

Страница 9: ...requency of driving that the system is still securely attached and tighten any parts that have worked loose The maximum permissible speed for vehicles with a receiver unit mounted on the roof and the...

Страница 10: ...damage Loosen the six fastening screws width A F 10 mm Carefully lift the turntable off the mounting plate and place it on the two prepared wooden supports Make sure that the cables are not crushed w...

Страница 11: ...For safety keep at least the required area free for ease of installation and any subsequent dismantling INSTALLATION AND CONNECTION Direction of travel Park position Recom mended clear space min 880...

Страница 12: ...rior of the vehicle directly underneath the turntable If you prefer a different method of laying the cables they can be run from the rear of the turntable via the channel provided in the mounting plat...

Страница 13: ...are always used to secure the glued mounting plate Figure B INSTALLATION AND CONNECTION For very thin roof panel materials and insufficient support in the insulating material through holes 5 5 mm int...

Страница 14: ...gent within a circumference of 17 cm around the drilled hole and allow the surface to dry thoroughly If the surface is painted ensure that the paint finish is sufficiently well bonded to the substrate...

Страница 15: ...the mounting plate in place with the prepared screws evenly tightening six screws across the diagonals Note The adhesive sealant used is capable of filling small gaps caused by the curvature of the v...

Страница 16: ...e sealant to the six threaded holes in the mounting plate and screw the fastening screws into the thread Tighten the screws to a torque of 6 Nm To prevent water vapour from inside the vehicle reaching...

Страница 17: ...be crushed Do not try to pull the cables from the unit This could damage the cables or loosen the cable connections Place the turntable carefully on the mounting plate The through holes on the turnta...

Страница 18: ...has a turning range of 96 cm Drill hole with 38 mm Deburr sharp edges of hole Apply Sikaflex 291 adhesive to the spigot of the roof gland Insert the spigot into the hole and secure it from below with...

Страница 19: ...late on roof gland and secure with appropriate screws choose screws according to thickness structure of roof Screw turntable on to mounting plate using torque wrench Important Tightening torque 6 Nm S...

Страница 20: ...re when tightening the screws not to damage any cables etc behind or in the wall The receiver is designed for installation in exclusively dry interior locations The installation location must be prote...

Страница 21: ...iagram on the right and The attachment point is provided for sticking the infra red sensor directly to the unit The attachment point on the receiver is on the front panel see diagram on the right Conn...

Страница 22: ...e receiver support IMPORTANT INSTRUCTIONS FOR INSTALLATION Under no circumstances use countersunk head screws for installation see diagram on the right since these can damage the screw sockets on the...

Страница 23: ...M4 M6 or M8 and most importantly the permissible screw penetration depth Before starting any installation work it is essential you disconnect all the units concerned from the mains If the screws penet...

Страница 24: ...ver at the installation location previously selected and prepared Do not force it and take care not to damage either the screw sockets the receiver casing itself or any cables that are already attache...

Страница 25: ...supply or a 230 V supply via a power supply unit to the plug connector on the receiver Make sure that the inline integrated fuse 5 A of the cable is fully plugged in and is intact If the fuse blows th...

Страница 26: ...green connecting cable marked IGNITION allows you the option of connection to a circuit in the vehicle that is activated when the ignition key is turned and then carries a continuous 12 V supply This...

Страница 27: ...means that the automatic lowering function will not work Ensure the cable polarity is correct Figure G INSTALLATION AND CONNECTION CONNECTION EXAMPLE FOR 12 V BATTERY CONNECTION 6 pin brown white gre...

Страница 28: ...shown below The satellites broadcast the various channel packages in different footprints The respective channel packages can normally be received within these footprint zones In the marginal zones r...

Страница 29: ...els no longer used should be sealed with the integral plugs The enclosure is then watertight once again Note Before exchanging the UFS 940sw first move the turntable to the park position ESC Electroni...

Страница 30: ...rom the orbital position of the satellite With deviations in the preferred reception range degree of longitude of more than 15 20 from the orbital position of the satellite it is possible to change th...

Страница 31: ...a secure position to stand and hold on while working The roof and the climbing equipment used e g ladder are dry clean and non slip The roof can withstand the weight of the person carrying out the re...

Страница 32: ...Start Search is displayed cancel this procedure by pressing the button 5 Press the green button 6 Use the buttons to move to the Antenna Configuration menu item Confirm the selection by pressing the...

Страница 33: ...rque of 6 7 Nm 14 Leave the installation location and reconnect the UFS 940sw to the power supply 15 First switch the receiver on at the main switch then press any of the numeric buttons The CAP 610 i...

Страница 34: ...d connected units are disconnected from the power supply The person carrying out the repairs does not suffer from vertigo and can move around safely on the roof of the caravan or motor home The person...

Страница 35: ...You will need a socket wrench for this size 19 mm Screwing in the M12 screw pushes the rocker off the tapered shaft and releases the engagement Important Insert the screw only as far as necessary to...

Страница 36: ...36 TECHNICAL SPECIFICATIONS DIMENSIONS MM Direction of travel Mounting plate 118 3 118 3 153 6 282 143 5 approx 17...

Страница 37: ...37 TECHNICAL SPECIFICATIONS Min recommended clearance 880 Rotary axis BAS 60 Roof gland Nut Clamping range 20 50 Weight incl BAS 60 approx 13 8 kg Mounting plate 145 5 including mounting plate 143 5...

Страница 38: ...K 13 3 13 7 Power supply vehicle battery V 10 9 13 8 Power consumption from the 12 V vehicle electrical system Inrush current Satellite search TV reception Stand by A Type 10 max 12 Type 3 Type 1 2 Ty...

Страница 39: ...urised heavy 64742 82 1 1 2 5 Xn N 10 65 51 53 66 67 265 185 4 4 4 methylene diphenyl diisocyanate 101 68 8 0 1 1 Xn 20 36 37 38 42 43 202 966 0 Xylol 1330 20 7 1 2 5 Xn 10 20 21 38 215 535 7 3 Potent...

Страница 40: ...that bind to liquids e g sand sawdust universal binding media Dispose of the material that has been cleared up in accordance with the section on Disposal 7 Handling and storage Handling Instructions...

Страница 41: ...hen handling the product Before breaks and after completing work wash hands well Breathing protection When ventilation is poor ABEK multi range filter The gas filter class is dependent on the local co...

Страница 42: ...is empty of residues should be sent for recycling Packaging that contains residues of hazardous substances or which is contaminated with hazardous substances and any packaging that is not empty of res...

Страница 43: ...mable 20 Hazardous to health if breathed in 20 21 Hazardous to health if breathed in and if comes in contact with the skin 36 37 38 Irritates the eyes breathing organs and the skin 38 Irritates the sk...

Страница 44: ...eckverfugung empfehlen wir Sikaflex 290 DC In erh rte tem Zustand kann Sikaflex 291 problemlos geschliffen werden H rtungsmechanismus Technical data sheet Version 12 2005 Sikaflex 291 The strongly bon...

Страница 45: ...en vorgesehenen Anwen dungszweck zu pr fen nderungen der Produktspezifikationen bleiben vorbehalten Schutzrechte Dritter sind zu beachten Im brigen gelten unsere jeweiligen Verkaufs und Lieferbedingun...

Страница 46: ...l 49 8031 184 700 The automatic overnight updating of the EPG data described in the UFS 940sw operating manual is not performed automatically when the UFS 940sw is being operated on the CAP 610 The EP...

Страница 47: ...installed and connected as described in the installation and operating manuals If you have not yet done so read the safety instructions at the beginning of the UFS 940sw operating manual and follow t...

Страница 48: ...Installation and Connection sections First switch your TV set on and select the AV or video HDMI channel number to which you have connected the receiver Switch on your receiver at the power switch on...

Страница 49: ...refer to the operating manual for your TV set and take care to select only those settings that your TV set can process Video Output via Select the connection on the receiver to which you have connecte...

Страница 50: ...the TV set must be switched on or off separately If you select On the TV set will be switched on automatically as the receiver starts up but only if the TV set was in stand by mode If the receiver is...

Страница 51: ...tomatically change over to and from summer and winter time If On is selected the receiver automatically sets itself to the right time If you select the setting Off you must make the change to and from...

Страница 52: ...enna line and press the button to confirm The following display appears RESETTING THE CAP SYSTEM TURNTABLE ANTENNA RESET All satellite positions found by a search will be deleted Press the button to c...

Страница 53: ...time Use the buttons to select the Input GPS position for CAP line and press the button to confirm The following display appears INPUTTING THE CAP GPS POSITION CAP MENU TURNTABLE ANTENNA SETTINGS The...

Страница 54: ...r No on detection of a satellite signal during manual alignment by the user STOP ON SIGNAL As soon as you switch the orange bar to the Move to the azimuth rotate the antenna line you will see the foll...

Страница 55: ...structures or other obstacles The settings are made using the cursor buttons or the numeric keys ELEVATION BORDER AND ELEVATION OFFSET In the fringe areas of the satellite footprints it may happen th...

Страница 56: ...tes generally about two minutes You will first see the following message As soon as the turntable has found the correct satellite it saves this position During this process you receive no TV picture T...

Страница 57: ...EL SELECTION FROM THE CHANNEL LIST When you open this list the channel list selection sort order is displayed from where you selected the last channel For instance you can use the buttons to display v...

Страница 58: ...hensive explanation of the channel list with its detailed functions e g the scan and sort function can be found in the UFS 940sw operating manual view the currently selected channel in the small windo...

Страница 59: ...f you know the GPS data for your new location refer to the item Inputting the CAP GPS position in the section CAP menu turntable antenna settings Inputting the GPS data for your current location allow...

Страница 60: ...tion to move the antenna manually Use the buttons to switch to the Move CAP to park position item and press the button to park the antenna 4 When the ignition is operated the antenna automatically mov...

Страница 61: ...power supply to the turntable and whether it is obstructed e g by a branch If neither of these causes of faults is displayed the turntable motor temperature is in the critical range Allow the turntabl...

Страница 62: ...to the CAP will remain disabled This means the CAP cannot be operated SPECIAL MESSAGES FROM THE TURNTABLE The turntable antenna has reached the mechanical stop or is jammed Check whether the turntabl...

Страница 63: ...nnection to the turntable is defective Reset the turntable in the CAP menu check the connections between the turntable and receiver or contact our service centre The receiver has lost communication wi...

Страница 64: ...the park position your recordings will not be performed To prevent the turntable rotating at a time when it is unsupervised or when rotation might be irritating e g in the middle of the night a timer...

Страница 65: ...65 DECLARATION OF CONFORMITY...

Страница 66: ...NCIL dated 27th January 2003 on used electrical and electronic appliances it must be disposed of properly At the end of its service life take this device for disposal at a designated public collection...