8
•
Areas with many insects – small insects entering the smoke chamber may
trigger unwanted alarms
•
A
reas where the temperature is outside the operating temperature of the
smoke detector (above 45 °C or below -10 °C), e.g. uninsulated attics, cold
storage rooms, boiler rooms, etc.
•
I
naccessible areas with very high ceilings – make it difficult to test the
smoke detector or mute the alarm
Mounting the Smoke Detector:
1.
Select an installation location as recommended under
“Place of Installation”.
2.
Use the bracket (5) as a template for drilling the holes.
3.
Mount the bracket on the ceiling using the two screws
supplied so that the two hooks (6) point downwards.
4.
To connect the smoke detector to the base, hold it against
the bracket so that the line indicated at the side is directly
below one of the hooks. Carefully hook the installation
recesses (4) onto the fixing hooks (6). Slightly push the
smoke detector upwards and turn it clockwise to lock it
into position.
Connecting the smoke detector FRM 100 and putting it into operation
1.
After inserting the batteries, you hear two brief signals and the LED begins to
flash. During the warm-up phase of six minutes, you can connect the smoke
detector with your alarm panel.
2.
Open the web interface of the alarm panel, go to the menu “Sensors”
“Add”
and press “Start”.
3.
Press the Learn button of the smoke detector. Two brief signals are emitted.
4.
The alarm panel will confirm the successful addition of the smoke detector with a
brief signal tone and display the sensor in the lower menu.
5.
Click “Add” to add the sensor to the sensors list.
Please note:
•
The smoke detector should be installed shortly after the batteries have
been inserted because the smoke detector adjusts to the environmental
conditions (dust intensity) on the place of installation.
•
After the warm-up phase (six minutes), the calibration phase starts. The
calibration phase takes between two and sixteen minutes and every 100
seconds, the smoke detector emits a brief signal. At the end of the
calibration phase, two brief signals are emitted if the calibration was
successful. If an error occurred, a continuous sound will notify you. If this
is the case, remove the batteries and begin anew from step 1.
•
During the calibration phase, the smoke detector cannot be added to the
alarm panel. This has to be done before or after the calibration phase.