6
Smoke Detector FRM 100
Product description:
You can install several smoke detectors on several floors, corridors and escape routes
to warn you of a fire ahead of time.
The smoke detector works according to optical principles. In a measurement
chamber, the concentration of smoke particles is measured. If the concentration
exceeds a set limit, the smoke detector will sound an alarm of 95 dB (measured from
a distance of 1 meter / 3.2 feet). Smoke detectors are designed to save lives, not to
prevent a fire. The smoke detector should be installed on the ceiling in the centre of
a room. A minimal distance of 50 cm (19.6 in) to walls, lamps, corners, decorations,
etc. should be maintained. The smoke detector can secure an area of approx. 60 sqm
(645 sqft). In case of fire the siren(s) of the alarm panel will likewise sound an alarm.
Sensor data:
Dimensions (without mount):
Ø 10.6 x 4.4 cm (4.17 x 1.73 in)
Weight:
220 g (0.48 lbs)
Place of installation:
Only indoors (walls, corners)
Operating temperatures:
-10 °C to +45 °C (14 °F to 113 °F)
Humidity:
Maximum 95% (non-condensing)
Radio frequency:
868.6375 MHz
Detection method:
Optical
Conforms to the following standards: DIN EN 54-7 and EN 14604
Internal siren:
95 dB / 1 m (3.2 ft)
1.
LED
•
After inserting the batteries, the smoke detector automatically enters a
calibration phase. During this time, the LED flashes and the smoke
detector can be connected to the alarm panel.
•
If the batteries run low, the LED flashes every 30 seconds.
•
When the smoke detector transmits a signal to the alarm panel, the LED
lights up.
2.
Learn button
Press the test button in the following cases:
•
To connect the smoke detector with the alarm panel
•
To perform a range test
•
To perform a function test