Malfunctions and Defects 

If you notice any kind of defect, remove the batteries from the glass breaking sensor 

FGM 100 and contact your retailer or KATHREIN Digital Systems GmbH directly. Any 

further usage of the system may lead to fire or electric shock! 

Intended Use 

The KATHREIN Digital Systems GmbH glass breaking sensor is designed for building 

security. Use the glass breaking sensor FGM 100 indoors only (there is no protection 

class for the glass breaking sensor). Any other use than that described in this manual 

is not permitted and will void any warranty or guarantee as well as liability claims. The 

same applies if the device is modified or retrofitted. 

Disposal 

 

Do not dispose of the device with domestic waste! 

This product complies with the EU Directive on waste electrical and 

electronic equipment (WEEE) and therefore must not be disposed of 

with domestic waste. 

Dispose of the device via your local 

collection 

point for waste electronic equipment! 

 
This product contains software programs subject to the GPL free software license. 

 
This product contains software that was developed by third parties and/or software 

subject to the GNU General Public License (GPL) and/or the GNU Lesser General 

Public License (LGPL). We will send you the source code of these programs on request. 

The GPL and/or LGPL code used and offered in this product is EXCLUSIVE OF ANY 

GUARANTEE WHATSOEVER and is subject to the copyright of one or several authors. 

For further details, please refer to the GPL and/or LGPL code of this product and to 

the terms of use of GPL and LGPL. 
 
You can read the complete license text a

http://www.gnu.org/licenses/gpl-2.0.html

. 

For an unofficial German translation, please go to  
http://www.gnu.de/documents/gpl.de.html. 

 

 

Содержание FGM 100

Страница 1: ...1 1 User Manual FGM 100 2220000017 Glass Breaking Sensor...

Страница 2: ...escriptions in this manual were compiled with the greatest care However KATHREIN Digital Systems GmbH cannot entirely exclude mistakes in this manual Therefore we do not assume any legal responsibilit...

Страница 3: ...re when operating the device in a commercial environment This product generates uses and may emit radio energy It may in addition interfere with other radio communication systems if not installed or u...

Страница 4: ...ctric power lines or magnetic fields as this may impair the transmission quality significantly Do not install the glass breaking sensor directly on iron or aluminium surfaces as this may impair the wi...

Страница 5: ...e on waste electrical and electronic equipment WEEE and therefore must not be disposed of with domestic waste Dispose of the device via your local collection point for waste electronic equipment This...

Страница 6: ...ndow Operating temperatures 10 C to 55 C 14 F to 131 F Humidity Maximum 85 non condensing Radio frequency 868 63 MHz 1 LED green internally 2 LED red internally 3 Microphone 4 Dip switch 5 Battery com...

Страница 7: ...ass breaking sensor 3 The sensor and the signal strength should be indicated The higher the indicated number the better the reception 1 9 4 Click Stop to end the test Please note If there is no signal...

Страница 8: ...re between the window and the glass breaking sensor Install the glass breaking sensor in an open space not in corners so that that sound waves can reach the sensor from as many sides as possible Do no...

Отзывы:

Похожие инструкции для FGM 100