ESO 005 Temperature Control
About This Guide
This document is part of the product. This document describes how to install and connect the ESO 005 temperature
control.
►
Do not install or use the device until you have read and understood this document.
►
Keep this document for reference throughout the service life of the device. Pass this document on to any new owner
or user.
For the most up-to-date version of this document, go to the Kathrein website
www.kathrein.com
.
Features
■
Dual mode temperature controller in the surface-mount housing
■
Cable glands and clamps for the power supply
■
Automatic switch-off if the sensor is disconnected or in case of a short circuit
■
Switch-on temperature at +3 ºC
Scope of Delivery
●
1 x ESO 005 temperature control
●
1 x PT 100 temperature sensor
●
10 x cable ties, 360 mm
●
1 x mounting plate
●
1 x tightening strap
Transport and Storage
►
Transport and store the device in its original packaging.
►
Transport and store the device only in the permitted temperature range between –30 and +80 °C. Make sure there is
no water condensation build-up.
Intended Use
The ESO 005 is an electronic temperature control for the ESO 95 and ESO 120 r
eflector heating systems. The ESO 005
is designed for use as an ambient thermostat for frost protection heating systems and surface thermostat with remote
sensor.
Any other use, or failure to comply with these instructions or documentation and instructions enclosed with the devices,
will result in voiding of warranty or guarantee.
The following circumstances result in the loss of all warranty and liability claims towards the manufacturer:
●
Improper Installation
●
Use of non-specified mounting materials, which cannot guarantee the mechanical reliability of the antenna system
●
Structural changes or interference with the components and mounting accessories in the kit, which could endanger
both the mechanical and functional reliability
●
Failure to observe installation and safety instructions in this manual
Tip
Keep these instructions for further reference, and if the unit passes to another owner, pass them on to the
new owner.
Functional Specification
If the temperature measured by the sensor lies below the fixed set point of +3 ºC, the relay closes and the heating
switches on. The heating is switched off if the sensor is disconnected or in case of a short circuit.