Environmental
conditions:
Kathrein cellular antennas are designed to operate under the environmental conditions
as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
– Low temperature: –55 °C
– High temperature (dry): +60 °C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.
Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.
Environmental
tests:
Kathrein antennas fulfil the stated specifications after completion of the environmental
tests as defined in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.
Please note:
As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.
The mechanical design is based on the environmental conditions as stipulated in
ETS 300 019-1-4. Wind loads are calculated according to DIN 1055-4.
The antennas may be used at locations where the anticipated peak wind velocity or
gust wind speed lies within the maximum wind speed listed in the data sheet. We
warrant the mechanical safety and electrical functionality under such conditions.
The wind speeds are defined in accordance with the DIN, EN or TIA standards. This
warranty makes allowance for the partial safety factors specified in those standards.
Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress
(e.g. strain caused by oscillating support structures), may result in the breakage of an
antenna or even cause it to fall to the ground. These facts must be considered during
the site planning process.
The details given in our data sheets have to be followed carefully when installing
the antennas and
accessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
connector of the same standard, otherwise damage may occur.
The tilt values will be set to any arbitrary value in the given tilt range. These values
are independent from the frequency band or antenna type and can vary between
antennas and bands.
EU-RED
Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
Any previous data sheet issues have now become invalid.
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
www.kathrein.com
Page 1 of 1
936.4694/d Subject to alteration.
General Information
about Panel Antennas
Our products are compliant to the
EU Directive RoHS as well as to other
environmentally relevant regulations
(e.g. REACH).
RoHS
Our quality assurance system and our
environmental management system apply
to the entire company and are certified
by TÜV according to EN ISO 9001 and
EN ISO 14001.