background image

Any previous data sheet issues have now become  invalid.

KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820

www.kathrein.com

Page 2 of 2

936.4037/a     Subject to alteration.

Installation of the feederline connector and RCU (optional):

In order to protect the adjustment mechanism, the protective caps have to be attached during 
 feederline installation!

Carefully place the connector and 
fi x the nut using a torque-wrench 
(according to the manufacturers 
guidelines).

After feederline installation, the 
optional remote control units 
(RCUs) can be mounted.

These tools are suitable for 7-16 connectors with a wrench size of 
27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a 
wrench size of 41 mm | 1.6 inches.

Tighten nuts within a torque range of 25 – 33 Nm depending on 
 connector manufacturers’ specifi cations, respectively the RCU nut 
with a torque range of 15 – 18 Nm.

Kathrein installation set: Type No. 85010077
Set has to be ordered separately!

Set consists of three spanners of divers width
27, 32 and 41 mm | 1.1, 1.3 and 1.6 inches

32 | 1.3

41 | 1.6

27 | 1.1

1/2˝ square actuation
according to
DIN 3120 Form C

All dimensions in mm | inches

Colour coding:

Correlation of each RF input to:
– the corresponding adjustment mechanism
– the frequency range
– the polarization

Ventilation hole

Spindle with tilting scale

7-16 female (long neck)

Adjustment mechanism

(protective cap removed)

General Instructions 
for Feederline and RCU Installation 
for Antennas

Please note: 

In order not to damage the interfaces, please make sure that only the right tools are used. 

Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench 
width.

Description of bottom end cap (exemplary picture):

Содержание 742215V01

Страница 1: ...1920 2200 Gain at mid Tilt dBi 17 5 18 2 Gain over all Tilts dBi 17 5 0 4 18 1 0 3 Horizontal Pattern Azimuth Beamwidth 68 2 0 63 3 4 Front to Back Ratio Total Power 30 dB 26 25 Cross Polar Discrimina...

Страница 2: ...n Loss dB 14 Interband Isolation dB 30 Passive Intermodulation dBc 150 2 x 43 dBm carrier Polarization 45 45 Max Effective Power for the Antenna W 500 at 50 C ambient temperature Values based on NGMN...

Страница 3: ...tenna Bottom view Dimensions refer to radome All dimensions in mm inches 54 2 1 155 6 1 70 2 8 45 45 Layout of interface B1 Correlation Table Frequency range Array Connector 1710 2200 MHz B1 1 2 KATHR...

Страница 4: ...alteration Suitable for mast diameter mm inches 42 115 1 65 4 53 Antenna mast distance mm inches 20 25 0 79 0 98 Material of clamp and screws Hot dip galvanized steel stainless steel Weight kg lb 1 1...

Страница 5: ...ed downtilt adjustment For a description of RCU installation please refer to the respective data sheet Remove the protective cap and the twist protection completely Twist protection Downtilt spindle w...

Страница 6: ...ten nuts within a torque range of 25 33 Nm depending on connector manufacturers specifications respectively the RCU nut with a torque range of 15 18 Nm Kathrein installation set Type No 85010077 Set h...

Страница 7: ...y factors specified in those standards Extraordinary operating conditions such as heavy icing or exceptional dynamic stress e g strain caused by oscillating support structures may result in the breaka...

Отзывы: