Any previous data sheet issues have now become invalid.
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
www.kathrein.com
Page 2 of 2
936.4037/a Subject to alteration.
Installation of the feederline connector and RCU (optional):
In order to protect the adjustment mechanism, the protective caps have to be attached during
feederline installation!
Carefully place the connector and
fi x the nut using a torque-wrench
(according to the manufacturers
guidelines).
After feederline installation, the
optional remote control units
(RCUs) can be mounted.
These tools are suitable for 7-16 connectors with a wrench size of
27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a
wrench size of 41 mm | 1.6 inches.
Tighten nuts within a torque range of 25 – 33 Nm depending on
connector manufacturers’ specifi cations, respectively the RCU nut
with a torque range of 15 – 18 Nm.
Kathrein installation set: Type No. 85010077
Set has to be ordered separately!
Set consists of three spanners of divers width
27, 32 and 41 mm | 1.1, 1.3 and 1.6 inches
32 | 1.3
41 | 1.6
27 | 1.1
1/2˝ square actuation
according to
DIN 3120 Form C
All dimensions in mm | inches
Colour coding:
Correlation of each RF input to:
– the corresponding adjustment mechanism
– the frequency range
– the polarization
Ventilation hole
Spindle with tilting scale
7-16 female (long neck)
Adjustment mechanism
(protective cap removed)
General Instructions
for Feederline and RCU Installation
for Antennas
Please note:
In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
Description of bottom end cap (exemplary picture):